*INSTALLATION*

Electrical connection

Danger of injury!

Miele cannot be held liable for
unauthorised installation,
maintenance and repair work as this
can be dangerous to users.

Connection to the electrical mains
may only be carried out by a
qualified electrician in accordance
with national and local regulations
and the additional regulations of the
local electrical supply companies.

Connection of this appliance must
comply with national and local safety
regulations.

Connection to a switched socket

 is

recommended as this provides easier
access in the case of a service call.

If the appliance is 

hardwired

 or if the

switch is not accessible after
installation, an additional means of
disconnection must be provided for all
poles.

Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3 mm. These
include isolator switches, fuses and
relays.

Voltage, rated load and fuse rating

are given on the data plate situated at
the front of the oven compartment.
Please ensure the connection data
matches the household supply.

When contacting Miele, please quote
the following:

- Model number

- Serial number

- Connection data (voltage/frequency/

maximum rated load)

If the mains connection cable is
damaged, it must be replaced by a
suitably qualified electrician with a
specialist connection cable of type
H 05 VV-F, available from Miele, in
order to avoid a hazard.

Temporary or permanent operation with
a self-sufficient or non-mains
synchronous energy supply system
(e.g. isolated networks, back-up
systems) is possible. A requirement for
the operation is that the energy supply
system complies with all current local
and national requirements that apply to
stand-alone, solar and/or battery
systems.
The protective measures provided in
the domestic installation and in this
Miele product must also be assured in
their function and operation in isolated
operation or in non-mains synchronous
operation, or replaced with equivalent
measures in the installation.

Wiring diagram

N.B. This appliance is supplied

single phase only in AUS/NZ.
The appliance must only be
connected in accordance with the
options below which include a
neutral conductor (see wiring
diagrams in thick-framed box). The
two connection options below the
thick-framed box are not permitted in
AUS/NZ.

Summary of Contents for H 2265-1 B

Page 1: ...nsions Dimensions are given in mm Installation in a tall or base unit When building the oven into a base unit underneath a cooktop please also observe the installation instructions for the cooktop as well as the building in height required for the cooktop ...

Page 2: ...11189580 08 Installation INSTALLATION Side view H 22xx ...

Page 3: ...11189580 08 Installation INSTALLATION Side view H 25xx H 27xx H 28xx A H 25xx H 27xx 43 mm H 28xx 47 mm ...

Page 4: ...11189580 08 Installation INSTALLATION Connections and ventilation a Front view b Mains connection cable length 1 500 mm c No connections permitted in this area d Ventilation cut out min 150 cm ...

Page 5: ...at insulation strips to the side walls of the housing unit Before installation Ensure that there is no power to the mains socket Follow the connection diagram supplied with the cooker Remove the housing cover to connect the single conductors of the power cable to the connection terminals All H 2xxx I cookers that are combined with an induction cooktop are also supplied with a ferrite ring With the...

Page 6: ...sing to lift the appliance It is a good idea to remove the door see Cleaning and care Removing the door and the accessories before installing the appliance This makes the cooker lighter when you push it into the housing unit and you do not run the risk of lifting it by the door handle Push the cooker into the base unit and align it Open the door if you have not removed it previously Secure the coo...

Page 7: ...ng unit Connect the mains cable from the oven to the electricity supply Do not carry the oven by the door handle The door can be damaged Use the handle cut outs on the side of the housing to lift the appliance It is a good idea to remove the door see Cleaning and care Removing the door and the accessories before installing the appliance This makes the oven lighter when you push it into the housing...

Page 8: ...es the household supply When contacting Miele please quote the following Model number Serial number Connection data voltage frequency maximum rated load If the mains connection cable is damaged it must be replaced by a suitably qualified electrician with a specialist connection cable of type H 05 VV F available from Miele in order to avoid a hazard Temporary or permanent operation with a self suff...

Page 9: ... CSA according to the diagrams shown Maximum rated load see data plate Possible combination cooktops Miele cookers with integrated cooktop controls may only be combined with cooktops as specified by Miele for use with that cooker Contact Miele for further information on suitable combinations Oven Ovens are supplied with a 3 core cable for connection to a 230 V 50 Hz alternating current supply Fuse...

Reviews: