Installation instructions
For Australia and New Zealand only:
Remote installation of underbench
oven
To install a underbench oven at "eye
level" a special accessory kit is re-
quired for connection to the hob.
This unit is obtainable from your Miele
dealer, or the Miele Spare Parts dept,
and consists of two 3.5 metre long con-
necting cable and an additional con-
nector box.
For the connection of the under-
bench oven H 212 E only one
power supply cable is required.
No data cable is needed.
The cable should be in conduit ap-
proved by the electricity regulatory
bodies. Only a suitably competent
person should install the connect-
ing cable from the control unit to the
hob.
The underbench oven must be built
in within view of the hob.
The cable conduit must meet statu-
tory electrical requirements and
have an inner diameter of at least
29 mm for the power cable.
The conduit length should be suffi-
cient to ensure the cable cannot be
touched for the whole distance be-
tween the additional connector box
and the control unit.
Do not install the oven directly
above a hob. Exposure to direct
heat could be damaging.
The oven must be separated by a
secured shelf from the rest of the
space in the wall unit, to make it in-
accessible.
63