Cleaning and care
Cleaning the spray arms
Particles of food can lodge in the spray
arm jets.
The spray arms should be inspected
and cleaned regularly (approx. every 6
months).
To do this remove the spray arms as fol-
lows.
Pull out the cutlery tray.
Unscrew the upper spray arm.
Lift up the middle spray arm
b
to en-
gage the tooth-wheel mechanism.
Then unscrew the spray arm
c
.
Remove the lower basket and take
out the lower spray arm.
Using a sharp pointed object push
the food particles into the spray arm
jets and rinse well under running
water.
Please note:
After replacing the spray arms check
that they move freely.
Cleaning and care