Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
49
Installing the refrigeration appliance
in a run of kitchen units
Risk of fire and damage due to
insufficient ventilation.
If the refrigeration appliance is not
ventilated sufficiently, the com-
pressor will run more frequently and
for longer periods. This will result in
increased energy consumption and a
higher operating temperature for the
compressor. This may, in turn, cause
damage to the compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the required
ventilation gaps. The ventilation gaps
must not be covered or blocked in
any way.
Top box
Refrigeration appliance
Housing unit
Wall
* The appliance depth is increased by
approx. 35 mm for refrigeration appli-
ances with wall spacers fitted.
The refrigeration appliance can be built
into any run of kitchen units and in-
stalled directly next to a kitchen fur-
niture housing unit. The appliance front
must protrude in front of furniture fronts
by at least 34 mm* at the sides and by
at least 55 mm* in the middle. This en-
ables the appliance door to be opened
and shut without being obstructed. To
match the height of the rest of the kit-
chen units, the refrigeration appliance
can be fitted with a suitable top box
.