Technical Information
50
DG 408x Steam Ovens
Option
Setting/Activation
Description
INDEX
CONTROL
ELECTRONIC
e.g., EPX 702
ID33795 V.2
The ID number of the control
electronic (2N1) is indicated.
POWER
ELECTRONIC
e.g., EPL 700
ID00796
The ID number of the power
electronic (3N1) is indicated.
FAULT INDEX
“No Faults” or fault code, e.g., “F 01”
All faults registered so far are
indicated; refer to Table 060-1.
Delete faults
All saved faults are deleted.
FUNCTION TEST
ALL OFF
All components are switched off.
HEATING CIRCUIT 1/
STEAM GENERATOR
(1R25)
On
Steam generator heater (1R25)
is switched on.
Off
Steam generator heater (1R25)
is switched off.
HEATING CIRCUIT 2/
STEAM GENERATOR
(2R25)
On
Steam generator heater (2R25)
is switched on.
Off
Steam generator heater (2R25)
is switched off.
LOWER HEAT ELEM.
or FLOOR HEATER
On
Floor heater R28 is switched on.
Off
Floor heater R28 is switched off.
FAN (M2)
On
The fan (M2) is switched on.
Off
The fan (M2) is switched off.
DOOR OPENER (Y56) On
The release element (Y56) is
activated and controls the door
opener via a metal rod, which
opens the door a crack.
Off
The door closes again slowly.
BUZZER
On
The buzzer sounds.
Off
The buzzer goes silent.
DISPLAY
The display alternately lights up
and goes dark.
SENSOR TEST
STEAM GENERATOR
CONTACT or STEAM
GENERATOR
CONTROL
Closed
Steam generator is inserted. The
steam generator switch (S84) is
switched on.
Open
Steam generator is not inserted.
LEVEL INDICATOR or
FILL INDICATOR
Closed
The steam generator is filled.
The level switch (S12) is
switched on.
Open
The steam generator is not filled.
DOOR SWITCH
Closed
Door is closed. Door contact
switch (S4) is switched on.
Open
The door is open.
TEMP INTERIOR
e.g., 81°F
The temperature at the PT 1000
temperature sensor (R30) is
indicated. (F06 if open circuited.)
KEYPAD or FUNCTION PAD PANEL
All keypads, with the exception of
“Timer” and “Off” (DG 4082) or
“Clear” and “Off” (DG 4080), can
be checked by touch.
RUNNING TIME
HEATING CIRCUIT 1
e.g., 0008h
The operating hours of heater
1R25 are indicated.
HEATING CIRCUIT 2
e.g., 0008h
The operating hours of heater
2R25 are indicated.
LOWER HEAT ELEM.
or FLOOR HEATER
e.g., 0005h
The operating hours of heater
R28 are indicated.
DESCALE or NO. OF
DESCALES
e.g., 1
The number of descales
performed is indicated.
Table 060-3:
Service Mode
Summary of Contents for DG 408 Series
Page 1: ...TECHNICAL INFORMATION DG 408x Steam Ovens 2012 Miele USA ...
Page 11: ...Technical Information 11 DG 408x Steam Ovens 010 Casing DG 4080 DG 4082 ...
Page 21: ...Technical Information 21 DG 408x Steam Ovens 020 Door DG 4080 DG 4082 ...
Page 24: ...Technical Information 24 DG 408x Steam Ovens 030 Oven Cavity DG 4080 DG 4082 ...
Page 29: ...Technical Information 29 DG 408x Steam Ovens 040 Water Tank ...
Page 38: ...Technical Information 38 DG 408x Steam Ovens 060 Fascia Electronics DG 4080 DG 4082 ...