background image

Before using for the first time

21

Touch the 

 control.

2

 will light up constantly, 

3

 will flash on

and off.

After a few seconds, 

2

 and 

3

 will flash

on and off. The connection has now
been disconnected.

Exit disconnection mode on the
ventilation hood by pressing the
delayed shutdown control 

.

The WiFi connection has now been
disconnected. A new connection can
now be set up.

Summary of Contents for DAS 4720

Page 1: ...nd Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance you must read these instructions before installing the appliance and using it for the first time en US M Nr 11 928 121 ...

Page 2: ... lighting on off 23 Power management 23 Safety shut off 23 Energy saving tips 24 Changing settings 25 Adjusting the grease filter filter saturation indicator 25 Adjusting or deactivating the filter saturation indicator for the charcoal filter 26 Deactivating power management 26 Cleaning and care 27 Stainless steel housing 27 Filter saturation indicator 28 Checking the filter saturation indicator 2...

Page 3: ...ndations 34 Installation materials 34 Installation materials for recirculation mode 35 Appliance dimensions 36 Distance between cooktop and ventilation hood S 39 Air venting 40 Non return flap 40 Condensate 41 Reducing Collar 41 Electrical connection 42 Technical data 43 Optional accessories for recirculation mode 43 ...

Page 4: ...losive Materials And Vapors This appliance is intended for residential use only Use only as described in these operating instructions This ventilation hood is not intended for outdoor use It must only be used to extract and clean vapors produced during cooking Any other use occurs at the owner s own risk Where a recirculation ventilation hood is installed above a gas cooktop please check that all ...

Page 5: ...be allowed to clean or service the hood Please supervise children in the vicinity of the hood and do not let them play with it The LED ClearView lighting is very intense Avoid looking directly into the light for prolonged periods of time Danger of suffocation Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the reach of children ...

Page 6: ...installation instructions Contact Miele s Technical Service Department for examination repair or adjustment Repairs and other work by unauthorized persons could be dangerous and may void the warranty A damaged ventilation hood can be dangerous Always check for visible signs of damage Never use a damaged ventilation hood Be certain your appliance is properly installed and grounded by a qualified te...

Page 7: ...in the Cleaning and care section of this manual Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults If the power cord is damaged it must only be replaced by a qualified service technician During installation maintenance and repair work the venti...

Page 8: ...en switched on the ventilation hood could draw flames into the filter Fat deposits could ignite presenting a fire hazard WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE ...

Page 9: ...n the ventilation hood on whenever a burner is in use to prevent damage from condensation Overheated oil and fat can ignite causing fire damage to the ventilation hood Do not leave cookware pans and deep fat fryers unattended when cooking with oil or fat Similarly never leave an open flame unattended when grilling Fat and debris deposits impair the proper functioning of the ventilation hood To ens...

Page 10: ...g do not damage electrical wiring and other hidden utilities d Ducted hoods must always be vented to the outdoors e Do not use this hood with any solid state speed control device To determine whether a ventilation hood may be operated above your cooking appliance please refer to the information provided by the appliance s manufacturer Safety regulations prohibit the installation of a ventilation h...

Page 11: ...cting duct material Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel burning installations If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK Cleaning a...

Page 12: ...e used the warranty may become void Defective components should be replaced by Miele original parts only Only with these parts can safety of the appliance be assured as intended by the manufacturer Miele will guarantee to supply functional parts for a minimum of 10 years and up to 15 years following the discontinuation of your ventilation unit ...

Page 13: ...or the proper functioning and safe use of the equipment Handling these materials improperly by disposing of them in your household waste can be harmful to your health and the environment Therefore please do not dispose of your old appliance with regular household waste and follow local regulations on proper disposal Consult with local authorities dealers or Miele in order to dispose of and recycle...

Page 14: ...Guide to the ventilation hood 14 ...

Page 15: ...ing the lighting on and off and for dimming the lighting h Control for switching the blower on and off i Controls for setting the blower power j Control for the delayed shutdown function k Control for the filter saturation indicator l Drop down front panel The front panel of the pull out canopy can be fitted with one that matches your kitchen cabinetry instead DML 2000 installation kit required ...

Page 16: ...tering through the intake is cleaned by the grease filters and conducted out of the building Recirculation mode only with conversion kit and charcoal filters as optional accessories see Technical data The air is drawn in and cleaned first by the grease filter and then by charcoal filters The air is then circulated back into the kitchen ...

Page 17: ...level indicators will flash Press and hold the control until the B indicator starts to flash Confirm the selection by pressing the operating hours control All the indicator lights will go out Extraction mode has now been set If the selection is not confirmed within 4 minutes the system will revert to the previous setting Setting up Miele home Required a WiFi network the Miele app a Miele user acco...

Page 18: ...ing via the app The Miele app can be used to connect to your network Install the Miele app on your mobile device To log in you will need 1 your WiFi network password 2 your ventilation hood password The password for your ventilation hood consists of the last 9 digits of the serial number This can be found on the appliance s data tag The data plate is visible once you have removed the grease filter...

Page 19: ...e delayed shutdown control The ventilation hood can now be operated via the app Connecting via WPS Your WiFi router must support WPS WiFi Protected Setup Switch the ventilation hood off Press and hold the control Press the lighting control at the same time 2 will light up constantly 3 will flash on and off The WiFi connection must be started on the ventilation hood at the same time as on the WiFi ...

Page 20: ...not connected WPS to your router quickly enough Repeat the steps above Tip If your WiFi router does not support WPS please connect via the Miele app Signing out of WiFi reset to factory settings To set up a new WiFi connection the existing WiFi connection must be disconnected Switch the ventilation hood off Press and hold the control Touch the lighting control at the same time With an existing WiF...

Page 21: ... will flash on and off After a few seconds 2 and 3 will flash on and off The connection has now been disconnected Exit disconnection mode on the ventilation hood by pressing the delayed shutdown control The WiFi connection has now been disconnected A new connection can now be set up ...

Page 22: ... after 5 minutes Selecting the delayed shutdown time It is advisable to run the blower for a few minutes after cooking has finished This helps to neutralize any lingering vapors and odors in the air It also reduces the risk of odors and residues accumulating in the ventilation hood The delayed shutdown function enables the blower to continue running for a pre determined time before switching itsel...

Page 23: ...ed with a power management system Power management helps to save energy It ensures that the blower power level is reduced automatically and that the lighting is switched off If the booster level is selected the blower automatically switches to level 3 after 5 minutes If the blower is set to level 3 2 or 1 it switches back one blower setting after 2 hours and then in 30 minute intervals until the b...

Page 24: ...wer hood power level and therefore benefit from reduced energy consumption Check the power level selected on the hood A lower power level is generally sufficient for the majority of cooking Only use the booster level when necessary When a large volume of cooking vapors are being produced switch to a high power level in good time This is more efficient than operating the hood for longer to try to c...

Page 25: ...ger cleaning interval of 40 or 50 hours if the customer uses very little fat when cooking Switch off the blower and the lighting Press the delayed shutdown control and the filter saturation control at the same time The grease filter symbol and one of the blower power level indicators will flash The indicators 1 to B show the current time setting 1 20 hours 2 30 hours 3 40 hours B 50 hours Press th...

Page 26: ...ll go out If the selection is not confirmed within 4 minutes the system will revert to the previous setting Deactivating power management Keep in mind that this may increase energy consumption Activating deactivating power management Switch off the blower and the lighting Press the delayed shutdown control for approx 10 seconds until the 1 indicator appears in the blower level display Then press i...

Page 27: ...es and control buttons using a small amount of warm water and liquid dish soap Apply with a sponge cloth After cleaning wipe the surfaces dry using a soft cloth Important information for appliances with stainless steel surfaces This information does not apply to the control buttons Stainless steel surfaces can be cleaned with a non abrasive cleaning agent designed specifically for use on stainless...

Page 28: ...shing indicators shows the elapsed operating time as a percentage Indicator 1 25 Indicators 1 and 2 50 Indicators 1 to 3 75 Indicators 1 to B 100 The number of elapsed operating hours remains stored in memory when the ventilation hood is turned off or if there is a power outage Grease filter Risk of fire An oversaturated grease filter is a fire hazard Clean the grease filter at regular intervals T...

Page 29: ...diluted dish soap Unsuitable cleaning agents Unsuitable cleaners can cause damage to the filter surfaces if used regularly Do not use any of the following Lime removers Abrasive powders or abrasive liquids Aggressive all purpose cleaners and degreaser sprays Oven sprays Cleaning the grease filter in a dishwasher Place the grease filter upright or slightly inclined in the lower basket Ensure the sp...

Page 30: ...e fan is turned on press the filter saturation indicator for approx 3 seconds until 1 is the only indicator flashing The grease filter symbol goes out When cleaning the grease filter before the full operating time has elapsed Press the filter saturation indicator for approx 6 seconds until 1 is the only indicator flashing Replacing the grease filter Regular usage and cleaning can cause the filter ...

Page 31: ...er The charcoal filters are listed under Technical data at the back of this booklet Installing replacing the charcoal filters The matching frames must be installed in order to use the charcoal filter Follow the directions on the installation sheet Remove the grease filter from the ventilation hood Remove the charcoal filter packaging Push the charcoal filters into the frames until they engage firm...

Page 32: ...ion indicator twice with the blower turned on and hold it for approx 3 seconds until 1 is the only indicator flashing The charcoal filter symbol will go out If you want to replace the charcoal filters before the full operating time elapses Press the filter saturation indicator twice and hold it for approx 6 seconds until 1 is the only indicator flashing Disposing of charcoal filters Used charcoal ...

Page 33: ...ent Please quote the model identifier and serial number of your appliance SN when contacting Miele Customer Service Both pieces of information can be found on the data plate Location of the data plate The data plate is visible once you have removed the grease filter and in the case of recirculation mode the charcoal filter Appliance warranty and product registration You can register your product a...

Page 34: ...ible The ventilation hood should be easy to reach and disassemble in case a service call is necessary This should be taken into consideration when planning the position of cabinetry shelves ceilings or decorative elements in the vicinity of the ventilation hood Installation materials 1 non return flap for fitting into the exhaust socket on the motor unit not needed for recirculation mode Depending...

Page 35: ...pliance for the consumer user 11839970 DML 2000 installation kit for installing a hinged front panel to match kitchen cabinetry not supplied available as an optional accessory Installation materials for recirculation mode You need the following optional accessories for recirculation mode DKFS 31 x installation kit contains 2 holders and 2 charcoal filters DKFS 31 900 P with single use charcoal fil...

Page 36: ...Installation INSTALLATION 36 Appliance dimensions Diagram 1 DAS 4720 in a 23 600 mm wide cabinet The drawing is not to scale ...

Page 37: ...Installation INSTALLATION 37 Diagram 2 DAS 4720 in a 30 762 mm wide cabinet DAS 4920 in a 35 900 mm wide cabinet The drawing is not to scale See diagram 1 for side view ...

Page 38: ...n with DUU 150 conversion kit b DML 2000 bracket accessory for installing a front panel In this installation situation the deflector plate is flush with the front edge of the cabinet niche If you wish to position the ventilation hood further forward or further back you must adapt the dimensions accordingly e g if you are using a front panel The height of the cabinet and the cut out dimensions must...

Page 39: ...iburner Gas Cooktops 43 000 BTU hr 12 6 kW no burner 15 000 BTU hr 4 5 kW 26 660 mm 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW no burner 16 500 BTU hr 4 8 kW 30 760 mm Multiburner Gas Cooktops 73 800 BTU hr 21 6 kW or one of the burners 16 500 BTU hr 4 8 kW Not possible Single Burner Gas Cooktops 20 500 BTU hr 6 kW 26 660 mm 30 760 mm Single Burner Gas Cooktops 20 500 BTU hr 6 kW 27 ...

Page 40: ...lat ducting The ducting should be as short and straight as possible Only use wide radius bends The ducting must not be kinked or compressed All connections must be strong and airtight If the ducting has flaps these must be opened whenever the ventilation hood is switched on Any constriction of the air throughput will reduce extraction performance and increase operating noise Ventilation stack If t...

Page 41: ...te Condensate traps for 5 125 mm or 6 150 mm diameter ducting are available as optional accessories When installing a condensate trap ensure that it is positioned vertically and as closely as possible to the ventilation hood above the exhaust vent The arrow on the casing indicates the direction of airflow Miele will not accept warranty claims for any functional defects or damage caused by inadequa...

Page 42: ...trical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Technical Service Department WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions WARNING Improper grounding can result in a risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providi...

Page 43: ...0 P or DKFS 31 R reactivatable The installation kits contain 2 charcoal filters and the required original equipment installation frames Charcoal filters DKF 31 900 P or DKF 31 R reactivatable must be purchased as an optional accessory The packs contain 2 charcoal filters WiFi module EK037 FCC ID 2ACUWEK037 IC 5669C EK037 This device complies with Part 15 of the FCC Rules and with Industry Canada l...

Page 44: ......

Page 45: ......

Page 46: ......

Page 47: ...n contacting Customer Service Canada Importer Miele Limited Headquarters and Miele Centre Customer Support Phone 888 99 MIELE 64353 info mieleusa com 161 Four Valley Drive Vaughan ON L4K 4V8 www miele ca Customer Care Centre Phone customercare miele ca 1 800 565 6435 905 532 2272 International Headquarters Miele Cie KG Carl Miele Straße 29 33332 Gütersloh Germany ...

Page 48: ...M Nr 11 928 121 00 en US DAS 4720 DAS 4920 ...

Reviews: