Cleaning and care
30
OdorFree Charcoal Filter
Recirculation ventilation hoods must be
fitted with a charcoal filter in addition to
the grease filter. This is designed to
absorb cooking odors.
It is fitted in the top of the ventilation
hood.
How to install/replace the charcoal
filter
Remove the charcoal filter from its
packaging.
Fit the charcoal filter into the holder in
the top of the ventilation hood.
When installing the filter for the first
time, activate the filter saturation
counter (see "Operation").
When to change the OdorFree
Charcoal Filter
Always replace the OdorFree
Charcoal Filter whenever it no longer
absorbs kitchen odors effectively.
Replace the filter at least once every
6 months.
The OdorFree Charcoal Filter saturation
counter
will light up to remind you to
change the charcoal filter regularly.
The OdorFree Charcoal Filter
saturation counter requires one-time
activation before use (see the
"Operation" chapter).
Resetting the operating hours
counter for the OdorFree Charcoal
Filter
If the operating hours counter is
activated, it must be reset each time the
filter is changed.
Press the OdorFree Charcoal Filter
button
for approx. 3 seconds with
the ventilation hood switched on until
only the indicator light for level
1
is
flashing.
The OdorFree Charcoal Filter symbol
will go out.
If you replace the OdorFree Charcoal
Filter
before
the full operating time
elapses:
Press the OdorFree Charcoal Filter
button
for approx. 6 seconds until
only the indicator light for level
1
is
flashing.
Disposing of the OdorFree Charcoal
Filter
Used OdorFree Charcoal Filters can
be disposed of with normal
household waste.
Charcoal filters are available to order via
the Miele website or from your Miele
dealer.
The charcoal filters are listed under
"Technical data" at the back of this
booklet.
Summary of Contents for DA 6996 W
Page 16: ...Guide to the appliance 16 ...
Page 32: ...Installation 32 Installation parts ...
Page 45: ......
Page 46: ......