Connection for air recirculation
If the site conditions are not suitable for
the cooker hood to be used for air ex-
traction, the appliance must be con-
nected for recirculation.
The following parts will be required:
– Conversion kit from extraction to re-
circulation (only for units or cooker
hood shafts which do not reach the
ceiling)
– Active charcoal filters
These parts are available from your
Miele Dealer or from the Miele Spare
Parts Department.
Connection
for units or cooker hood
shafts which do not reach the ceiling:
Saw out an opening in the cupboard.
From above, place the hose with the
directional grille through the hole in
the unit onto the exhaust connection
of the cooker hood so that the air out-
let points in the desired direction.
NB: on no account should it point to-
wards the wall.
Screw the directional grille to the unit
with two screws.
If a panel is to be used to extend the
wall unit or the cooker hood shaft to the
ceiling a suitable cutout must be made
in the panel.
Connection
for cooker hood shafts
which reach the ceiling:
Install a directional grille, available
from builders’ merchants, in the
upper region of the cooker hood
shaft so that the air outlet points in
the desired direction. NB: on no ac-
count should it point towards the wall.
Attach the recirculation hose.
Insert the active charcoal filters (see
section “Cleaning and care”).
Connection for air recirculation