Installation
Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
The following minimum distances
must be maintained between the
cooker hood and the hob:
– 45 cm for electric hobs
– 65 cm for gas hobs (see also
Warning and Safety section).
A distance of 65 cm above electric
hobs may be preferable to give more
working space.
Fitting the non-return flap
(for air extraction mode only;
not for ...EXT models)
Locate the non-return flap in the ex-
haust socket so that you can open
the flaps upwards.
Turn the non-return flap slightly anti-
clockwise to secure it.
Fitting the adaptor
(not for ...EXT models)
Take the largest adaptor possible.
The larger the diameter - the higher
the exhaust suction and the quieter
the running noise.
Put one of the adaptors supplied
(ø100 mm or ø120/125 mm) on the
exhaust socket and turn anti-clock-
wise to connect the adaptor firmly
with the exhaust socket.
Installation