All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with national and local
safety regulations
(BS 7671 in the UK).
Installation, repairs and other work
by unqualified persons could be
dangerous, for which the
manufacturer cannot be held liable.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
Do not connect the appliance to the
mains electricity supply by an
extension lead. These do not
guarantee the required safety of the
appliance.
The voltage and connected load are
given on the data plate
. This is visible
when the vapour plates are removed.
Ensure that these match the household
mains supply.
Connection of this appliance should be
made via a suitable isolator or a double
pole fused spur connection unit which
complies with national and local safety
regulations and the On-Off switch
should be easily accessible after the
appliance has been built in.
When switched off there must be an
all-pole contact gap of 3 mm in the
switch (including switch, fuses and
relays according to EN 60 335).
If the switch is not accessible after
installation (depending on country), an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
Important
U.K., IRL, NZ, ZA: This appliance is
supplied for connection to an a.c.
230 V single phase 50 Hz supply.
AUS: This appliance is supplied for
connection to an a.c. single phase
240 V, 50 Hz supply.
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
WARNING:
THIS APPLIANCE MUST BE
EARTHED
Electrical connection
33
Summary of Contents for DA 489-4
Page 10: ...Guide to the appliance 10 ...
Page 28: ...Assembly parts Installation 28 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...Alteration rights reserved 3906 M Nr 06 958 270 00 gb GB ...