Installation
46
When fitting a 900 mm wide rangehood
into a 900 mm wide housing unit
without side base supports, the
retaining brackets supplied are used to
align the rangehood and provide
additional support. The retaining
brackets are secured to the back panel
of the wall unit. If the wall unit does not
have a solid back panel, the rangehood
can be secured directly to the wall
using the screws and plugs supplied.
An angled key is supplied in case the
screws are difficult to access.
Loosen the retaining bracket screws
and push the bracket back against
the rear wall.
Align the rangehood and mark the
position of the fixing holes in the wall
unit.
Now secure the brackets to the wall
unit.
Realign the rangehood and tighten up
the screws on the housing unit.
Alternatively, the retaining brackets
can be secured to the top of the
housing unit. To do this, secure the
retaining brackets to the front fixing
points.
Use the adhesive covers supplied to
conceal the fixing holes which are not
used.