Installation
44
For safety reasons, it is essential that
the rangehood is only fitted into a
wall unit which is already installed. It
cannot be fitted into the wall unit
before the wall unit is installed.
Fit the rangehood into the wall unit
from below. Guide it back over the
safety notches until it is correctly
hung in the wall unit.
To secure the rangehood in the wall
unit, the deflector plate must be
extended. Electrical connection is
required to do this.
Before connecting the rangehood to
the electricity supply, please read
the "Electrical connection" and
"Warning and Safety instructions"
sections of this booklet.
Plug the connection cable into an
electrical socket.
Press the "
" button on the remote
control.
The motor switches on, the deflector
plate comes out.
When the deflector plate is extended,
disconnect the rangehood from the
electricity supply.
The motor will switch off, the deflector
plate remains extended.