Set up for extraction mode
^
If the on-site ventilation system does
not have a
non-return flap
, then the
non-return flap supplied with the
appliance must be fitted in the
exhaust socket in the motor unit.
^
The appliance is set up for use with
C
150 mm ducting. If
C
125 mm
ducting is required, the reducing
collar supplied must be fitted to the
exhaust socket (see section
"Connection for air extraction").
^
Secure the ventilation ducting over
the exhaust socket on the cooker
hood using a hose clip.
^
See "Connection for air extraction" for
further instructions on fitting the
ducting.
Set up for recirculation mode
If site conditions are not suitable for the
cooker hood to be used with air
extraction, the appliance must be set
up for recirculation.
For this, we recommend using the
conversion kit available from your Miele
dealer or the Miele Spare Parts Dept
(see "Technical data").
You will also need a charcoal filter (see
“Technical data”).
^
Attach the ventilation ducting to the
underside of exhaust grille.
^
Then feed the ducting down into the
housing unit through the opening at
the top.
^
Secure the ducting over the exhaust
socket on the cooker hood using a
hose clip.
A non-return flap is not used in
recirculation mode.
Installation
26