Warning and Safety instructions
9
In order to ensure safe operation and to prevent gases given off by
the heating appliance from being drawn back into the room when
the cooker hood and the heater are both operated simultaneously,
an underpressure in the room of 0.04 mbar (4 Pa) is the maximum
permissible.
Sufficient ventilation can be maintained by air inlets which cannot
be blocked, e.g. in windows, doors and outside wall vents. The
cross-section of the inlet openings must enable sufficient
ventilation. A ventilation brick alone is not generally sufficient to
ensure safe ventilation.
The overall ventilation condition of the dwelling must be taken into
account. If in any doubt, seek the advice of a competent building
regulations inspector or qualified gas fitter (GasSafe in the UK).
If the cooker hood is being operated in recirculation mode,
whereby the air is redirected into the room in which it is installed,
the above restrictions do not apply.
Summary of Contents for DA 2808
Page 14: ...Guide to the cooker hood 14 ...
Page 40: ...Installation INSTALLATION 40 Appliance dimensions DA 2808 ...
Page 41: ...Installation INSTALLATION 41 DA 2808 EXT EXTA ...
Page 53: ......
Page 54: ......
Page 56: ...M Nr 11 742 760 00 en GB DA 2808 DA 2808 EXTA ...