Installation of multiple
appliances
When installing more than one combiset appliance, a support bar
b
must be
installed between the appliances.
Countertop cut-out
two appliances
For the installation of
two appliances
the width of the countertop cut-out D is
the sum of A and C.
A
,
B
and
C
= appliance width
11 5/16", 15" or 22 11/16"
(288 mm, 380 mm or 576 mm)
minus 5/16" (8 mm)
to allow for the
overhang
D
= width of the countertop cut-out
Countertop cut-out
three appliances
For the installation of
three appliances
the width of the countertop cut-out D is
the sum of A and B and C.
If
more than three appliances
are
being installed, you will need to add,
A, B or C for each additional
appliance.
Installation
28
C
D
A
b
(500 mm)
+
- 1
11/16"
19
C
D
A
B
b
(500 mm)
+
- 1
11/16"
19