Supervisor level
85
Disinfection prog. code
A code has to be entered to cancel a
disinfection programme. The code can
be modified.
The code is:
0 0 0
Tip:
Make a note of your new code if
you ever change it.
Temp reduction
The suds temperature can be reduced
to prevent the suds from boiling too
early in high-altitude locations.
Factory default: Off
Automatic dispensing
Automatic dispensing via an external
dispensing system can be activated
Factory default: Off
Adjustment value dosage 1–6
To respond to the tolerances that oc-
cur in the pump system over time, the
dosage amount (ml/min) for the
pumps can be corrected.
The calibration value can be reduced by
3 increments or increased by 3 incre-
ments.
The calibration value is increased or re-
duced by 1, 2 or 3 times the adjustment
value based on the selected incre-
mental setting.
The calibration value and the adjust-
ment value must be added to the data
for the dispenser pumps by the Miele
Customer Service Department.
COM module selection
This washing machine is equipped
with an integrated WiFi module. How-
ever, the washing machine can also be
equipped with an external module.
- Off (factory default setting)
- Internal module
The internal WiFi module is used.
- External module
An XKM module or RS232 module is
inserted into the module slot.