![Midtronics MCC-070 Instruction Manual Download Page 17](http://html1.mh-extra.com/html/midtronics/mcc-070/mcc-070_instruction-manual_1792866017.webp)
MCC-070 Controlled Charger
Midtronics BV Hoofdveste 6-8 3992 DG Houten
www.midtronics.com
17
Chapter 2: Charging
While this screen is displayed the charger is actually
continuing to charge the battery in the background,
filling it to maximum capacity. The charger will continue
to do this until the battery’s acceptance of the charge is
100%.
10. Press Continue to exit the top-off charge and display the
Charge Results.
Charge Results
Charge Results
Good Battery
Voltage: 12.82V
Ah Replaced:
50Ah
Chemistry
Flooded
Time Elapsed:
01:17:45
Total
Charge
Time
Replaced
Amp
Hours
Measured
Voltage
Battery
Chemistry
Good Battery
: Battery is fully charged and ready to use.
Voltage
: Measured voltage at the battery terminal.
Ah Replaced
: Amp hours replaced in the battery.
Chemistry
: Battery chemistry selected by the technician.
Time Elapsed
: The elapsed time for the total charging session.
Possible Battery Decisions
Battery Decision
Recommended Action
GOOD BATTERY
Return the battery to service.
CHECK CONNECTION Possibly a poor connection
between the charging cables and
the battery.
BATTERY UNSAFE TO
CHARGE
Use a battery tester or diagnostic
charger to further analyze the
battery.
Risk of explosive gases
Charging a battery with a bad cell
may cause the battery to explode.
Possible Warnings
Warning
Recommended Action
OVERVOLTAGE
The charge cannot be continued
due to an overvoltage problem.
UNDERVOLTAGE
The charge cannot be continued
due to an undervoltage problem.
HIGH TEMPERATURE
The charge cannot be continued
due to an overheating problem.
OVERCHARGE
PROTECTION
The charge cannot be continued
due to an overcharging problem.