Chapter 2: Charging
Reflash
Reflash
Use Reflash (also known as Power Supply) to test
and maintain battery voltage in a vehicle at 13.5
volts to allow for uninterrupted reprogramming
of vehicle’s computer, retain vehicle system
settings, or simply to maintain battery voltage.
1. At the Main Menu, select the Reflash icon.
2. The VIN number can be added to the charge. If at the top
no VIN is shown, you can add the VIN through manual en-
try, CVG entry or selecting the vehicle in the vehicle list.
3. Select the battery Chemistry
4. Select the reflash Voltage Limit.
Cancel Confirm
Use
to highlight each number
and press
.
Select Confirm to save and continue or
Cancel to return to the Reflash screen.
5. Select Start.
The charger performs a Safety Check on the connected
battery.
Battery unsafe to
charge.
Attention
Cancel
Retry
If the battery passes, the charging process begins.
Use
or
to view the charging screens while the battery
is being charged.
6. Press
to abort the charging session.
7. The Charge Complete screen is displayed at the end of the
charge cycle.
Charge Complete!
Continue
8. While this screen is displayed the charger is actually con-
tinuing to charge the battery in the background, filling it
to maximum capacity. The charger will continue to do this
until the battery’s acceptance of the charge is 100%.
9. Press Continue to exit the top-off charge and display the
Charge Results.
Manual Charge
Manual
Charge
Use Manual Charge for a user-customized timed
charge ranging from 5 to 120 minutes or a
continuous charge that ends when the STOP
button on the charger is pressed.
1. At the Main Menu, select the Manual Charge icon.
2. Select the battery Chemistry.
3. Select the Charge Limit Type; Voltage or Current.
4. Select the Charge Limit Value.
Cancel Confirm
Use
to highlight each number
and press
.
Select Confirm to save and continue or
Cancel to return to the Reflash screen.
5. Select the Time Limit Type.
6. Select the Time Limit Value.
Cancel Confirm
Use
to highlight each number
and press
.
Select Confirm to save and continue or
Cancel to return to the Reflash screen.
7. Select the Temperature Limit.
Select Start.
The charger performs a Safety Check on the connected
battery.
Battery unsafe to
charge.
Attention
Cancel
Retry
If the battery passes, the charging process begins.
Use
or
to alternate the charging screen view while
the battery is being charged.
8. Press
to abort the charging session.
9. The Charge Complete screen is displayed at the end of the
charge cycle.
Charge Complete!
Continue