41
•
Volts/Amp
(requires the optional amp clamp)
The volts/amp meter simultaneously measures charging voltage and charging current.
1. Connect the
amp clamp lead
to the EXP’s accessories port.
2. Select the meter’s icon.
. Select the amp clamp range.
1 70 AMP MAX.
2 700 AMP MAX
.
Press the
NEXT
soft key to continue.
4. The meter will zero itself and display the amperage and voltage measurements.
5. Place the clamp’s jaws around the negative (–) cable.
6. Connect the battery test cable to the EXP.
7. Connect the battery test clamps in the correct polarity: red clamp or probe to positive (+);
black to negative (–).
8. The EXP will display the measurement
.
9. To return to the METERS menu, press the
END
soft key
.
Chapter 9: Digital Multimeter