GR-1 OPERATING STEPS 

 

 

IMPORTANT NOTES: 

 

Clean the battery terminals.  If stud adapters are required, fasten them with the proper tool. Do not 
use the battery clamps to tighten adapters. 

 

Use stud adapters on Side-Post

 

and/or Truck batteries that are not in the vehicle. 

 

Never remove the clamps from a battery to abort an active charging session.  Always use the 
STOP 

 

button before removing the clamps.

 

 

Do not leave clamps lying in battery acid.

 

 

Attach clamps to clamp-holder bar when the GR-1 is not in use.

 

 

Clean up any acid spills immediately (e.g., with baking soda and water). 

 

Clamps must be cleaned after every use.

 

 

 
1.  CONNECT GR-1 TO BATTERY  

Connect the GR-1 charging clamps to the battery in accordance with all precautions and safety instructions. 
 

2.   CONNECT TO AC POWER 

Plug the GR-1 into a dedicated, grounded 16 Amp AC outlet.  
Do not use an AC line cord adapter or extension cord. 
Toggle the power switch to the I (ON) position. 
 
The user will be informed if any side of the GR-1 clamp is not  
making good contact. 
 
If you accidentally reverse the clamp connections, the GR-1 will  
indicate this with a message and an audible alarm.  Toggle the  
power switch to the O position and return to GR-1 Operating Steps (1) 

 

3.  SELECT GR-1 MODES 

Use the UP/DOWN 

 buttons to select the mode:  

Diagnostic Fast Charge, Manual Charge or Jump Start Vehicle. 

 
Press the ENTER   button to continue. 
 

DIAGNOSTIC FAST CHARGE (12 V) 

If Diagnostic Fast Charge is selected use the UP/DOWN 

  

buttons to select the location of the battery: In Vehicle or  
Out of Vehicle. 

 
Press the ENTER   button to continue. 
 
If the selected location for the battery was Out of Vehicle, go to GR-1 Operating Steps (4) 
 
If the selected Battery Location was In Vehicle, use the  
UP/DOWN 

 buttons to select the location for connecting the  

clamp: At Battery Post, At Jumper Post, or At Side Post. 

 
Press the ENTER   button to continue.  Go to GR-1 Operating Steps (4) 
 

MANUAL CHARGE (12 and 24 V) 

If the selected Mode was Manual Charge, go to GR-1 Operating Steps (4) 
 

JUMP START VEHICLE 

If the selected Mode was Jump Start Vehicle, see GR-1 Functions (3) 
 

4.  SELECT TYPE 

Use the UP/DOWN 

 buttons to select the battery type:  

Lead Acid Battery(12V or 24V), AGM/Spiral Battery(12V),  
GEL Battery(12V) or Truck (12V). 

 
Press the ENTER   button to continue. 

     GR-1 240 BMC V1.00

 

      © Midtronics, Inc.2002

 

 Check Clamp Connections

 

 Charger Clamps Reversed

 

Select  Mode                    

   

Diagnostic Fast  Charge     

 

Battery Location               

   

In Vehicle                            

 

Clamp Location                

   

At Battery Post                   

 

Select Type                     

   

Lead Acid Battery (12V)    

 

Summary of Contents for GR1 240

Page 1: ...MODEL GR1 240 BATTERY MANAGEMENT CENTER INSTRUCTION MANUAL ...

Page 2: ...2 ...

Page 3: ...2 8 Enter Charging Time Manual charge only 12 GR 1 Functions 13 1 Diagnostic Fast Charge 12 V 13 Diagnostic Charging 13 Fast Charging a battery 13 Top Off mode 14 Diagnostic Acceptance charge 14 2 Manual charge 12 and 24 V 14 Timed charging between 5 and 120 minutes 14 Continuous charging 15 3 Jump Start Vehicle 15 OPTIONS 16 1 View BMC Code 16 2 View last test data 16 3 Print last test data 16 4 ...

Page 4: ...EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS NO FLAMES SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS DANGER POISON Always use the following precautions when working with batteries PRECAUTIONS ...

Page 5: ...result in a risk of fire electric shock or injury to persons 6 To reduce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting GR 1 7 Position AC and DC leads to avoid tripping over them and to prevent damage by hood doors or moving engine parts protect from heat oil and sharp edges 8 Do not operate GR 1 if it has received a sharp blow been dropped or otherwise ...

Page 6: ...ve grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc 2 Use stud adapters on side post and or Truck batteries that are not in the vehicle 3 Be sure area around battery is well ventilated while battery is being charged Using a piece of cardboard or other nonmetallic material as a fan can forcefully blow gas away 4 Clean battery terminals ...

Page 7: ...hift an automatic transmission to P 2 Locate GR 1 as far away from battery as GR 1 cords permit and position AC and DC cords to avoid stepping on or tripping over them and to prevent damage by hood doors or moving engine parts 3 Stay clear of fan blades belts pulleys and any other parts that can cause physical injury 4 Turn OFF all vehicle loads including door lights and correct any defects in car...

Page 8: ...hicle loads are OFF to prevent a possible arc FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE A SPARK NEAR BATTERY MAY CAUSE AN EXPLOSION TO REDUCE RISK 1 Check polarity of battery posts POSITIVE post usually has larger diameter than NEGATIVE post 2 Connect POSITIVE RED GR 1 clamp to POSITIVE post of battery Connect NEGATIVE BLACK GR 1 clamp to NEGATIVE post of battery ...

Page 9: ...ed in series OUTPUT RATINGS DC Voltage Amps Type of charge Charge time 12 V 10 A Slow charge Continuous 12 V 30 A Medium charge Continuous 12 V 60 A Fast charge Continuous 12 V 80 A Boost charge 1 minute max on 3 minutes max off 12 V 250 A Engine start 5 seconds max on 3 minutes min off 24 V 30 A Medium charge Continuous INPUT RATINGS 230 V AC 6A 9A 23A 50Hz SPECIFICATIONS ...

Page 10: ...service technicians Improper use of this connector will result in damage to the GR 1 The handle which attaches to the back panel includes a clamp holder bar When used consistently this feature adds safety convenience and longer operating life to the clamps cables and GR 1 OPERATION The UP DOWN buttons are used for scrolling through selections on the display and to increase decrease displayed value...

Page 11: ...e the power switch to the O position and return to GR 1 Operating Steps 1 3 SELECT GR 1 MODES Use the UP DOWN buttons to select the mode Diagnostic Fast Charge Manual Charge or Jump Start Vehicle Press the ENTER button to continue DIAGNOSTIC FAST CHARGE 12 V If Diagnostic Fast Charge is selected use the UP DOWN buttons to select the location of the battery In Vehicle or Out of Vehicle Press the EN...

Page 12: ...e was Diagnostic Fast Charge the charging cycle will begin If the selected Mode was Manual Charge go to GR 1 Operating Steps 8 See also GR 1 Functions 1 8 ENTER CHARGING TIME Manual Charge Only If the selected Mode was Manual Charge use the UP DOWN buttons to select the desired charging time from 5 minutes up to Continuous Charge Press the ENTER button to begin the timed charge Using the UP button...

Page 13: ...e tone FAST CHARGING A BATTERY The GR 1 controls the charging voltage and charging current based on its analysis of the diagnostic testing data diagnostic charging data and the battery information that was selected by the user It continuously monitors the battery and analyzes the charging progress during the entire timed automatic charging session In some cases the GR 1 may find a battery to be de...

Page 14: ...harging current then what normally is used The Diagnostic Acceptance Charge mode will switch the charging current at fixed time intervals in an effort to fully charge the battery When the GR 1 detects that the battery picks up charging current it can switch over to the Diagnostic Fast Charge mode again CHARGE COMPLETION When Diagnostic Acceptance Charge is complete the GR 1 will alert the user wit...

Page 15: ...R 1 will measure and record the final parameters of the battery Details can be found on the print out When the measurement is complete the GR 1 will sound an audible alarm and display the following information battery voltage available starting current in CCA charging mode and the final amount of charge put back into the battery shown in Ah The audible alarm will sound every 30 seconds until the u...

Page 16: ...R button to display the results for the most recently completed charge session The GR 1 saves the following final test data battery voltage available starting current in CCA total charging time battery condition and the final amount of charge put back into the battery shown in Ah Press the INFO button to return to the Options menu 3 PRINT LAST TEST DATA Press the INFO button Use the UP DOWN button...

Page 17: ...S number 4 The Internal Memory Error message means that an internal error has occurred in the GR 1 and it should be sent back for service OPERATION 1 The ON OFF switch is toggled to the on position but the GR 1 does not power up a Make sure the AC power cord is completely inserted into the AC outlet b Make sure the AC outlet is live check fuse or circuit breaker c Check the AC power cord for damag...

Page 18: ...OPERATING 1 Locate the handle and hardware provided 2 Position the handle so that the angle faces away from the back of the GR 1 and so that all mounting holes line up Refer to the drawing 3 Use all 4 screws to attach the handle to the back of the GR 1 GR 1 ASSEMBLY NOTES ...

Page 19: ...19 ...

Page 20: ... 0 08 European patent 0 548 266 Japanese patent 3006800 and other U S and Foreign patents issued and pending This product may utilize technology exclusively licensed to Midtronics Inc by Johnson Controls Inc and or Motorola Inc www midtronics com Toll free in North America 800 776 1995 P N 168 591B GB Europe03 05 2005 Midtronics Inc All rights reserved Midtronics Canada Inc 54 Ferris Drive P O Box...