Mod Bus
– a standard protocol used for communications. We have published our protocol to allow users to interface with the
Classic. See
www.midnitesolar.com
for our Mod Bus protocol.
Pwr Save
– Allows you to adjust the time the Backlight stays on.
Resting
– The Classic is not charging the battery due to low light. For certain reasons Resting will appear. Please see page 24.
T-Comp
– Temperature compensation using a temperature sensor to measure the ambient temperature of the battery bank and
will adjust the voltage set points up or down accordingly to ensure a full battery. There are 3 parameters to set Minimum and
Maximum adjusted voltage as well as volts per degree C per Cell. Typically this is -5 mV but please consult your battery
manufacturer. See page 19 for Temperature compensation info.
Tweaks
– This menu has all the advanced adjustments for the Classic. For example: Voltage off set adjustments etc.
VBatt
– Battery voltage, measured at the battery terminals of the Classic.
VOC
– Open Circuit Voltage, unloaded voltage measurement.
Vpv
– Input voltage, measured at the input terminals of the Classic.