Part name
:
1 – air breather 2 – O ring 3 – gasket of water softener
4 – water softener 5 – connecting hose (water softener)
Removal and replacement
1. Take
off
cutlery basket
,
basket
and
filter system
.
2.
Remove
shell
.
(see shell removal and installation)
3. Take out two
corner boards
,
absorber sound
,
backboard
,
hollow plate
.
4. Remove tank assembly.
(see tank assembly removal and installation)
5. Pull out the air breather, take out two O rings
6. Take out gasket of water softener (2), and pull out connecting hose (water softener).
7. Pull out all terminals for connecting water softener.
8. Reverse the above procedure to install. And check out all connectors connects well.
Note
: only use for some model have water softener.
1
2
3
4
5
Terminals