background image

10)
Excess CO .

2

10)
Adjust pressure when using CO  as low as possible, 

2

however, remembering that the applied pressure 
must be slightly higher than the internal pressure of 
the beer (no more than 18 lbs. should be applied.)
The colder the beer and the higher the applied CO

pressure, the more rapid the absorption of CO by 

 

the beer. This over-carbonates the beer, causing 
Wild Beer.

11)
Not enough pressure.
No pressure.

11) 
Check for defective air vents. (see Flat Beer, 
Corrections #3 and 4.)
Always turn pressure on before drawing beer.

12)
Old Beer.

12)
Rotate stock. The oldest beer should be tapped first; 
if beer has been allowed to stand in warm temperature 
beyond 45

°

 for any excessive length of time, it may 

begin secondary fermentation.
Store beer at 40

°

 all year round.

TAIL END BEER

Beer draws well at the beginning of the barrel. Towards the end of the barrel the beer is flat. This is more 
likely to occur when beer turnover is slow.

Causes

Corrections

Where air is used as a pressure source, 
air replaced the CO  in beer causing flat 

2

beer. Where beer is being drawn rapidly 
this problem is not so evident.

Wherever possible CO  Gas should be used as 

2

pressure source.
In high pressure systems where CO  gas cannot be 

2

sued a banner air-gas Blender should be installed. 
This introduces a small amount of CO  back into the 

2

beer, thus

Answers to FAQ

As for the following simple questions, you can try to solve them by yourself. If there is no 
change, please call the after-sales service department.

Fault

Possible reasons

The beer machine doesn't 
work.

Frequently switch machine.
The door cannot be closed 
properly.

Beer barrel is not in place.
The beer machine is not placed flatly.
The door is installed wrongly.
Shelf, metal plate or beer kegs are misplaced

Noise 

Whether the direction of the wheel is determined, 
or the cabinet is not placed smoothly.
The noise is the sound of refrigerant flow, which 
is normal.
In the end of each loop, you will hear the gurgle of
 refrigerant flow from the beer machine.
The contraction and expansion of the inner wall 
may cause pops and crackles.

Whether the power supply and plug is well placed.
Whether the voltage is too low.
Whether the new circuit trips, or the fuse melts.

Frequently switch machine.

The indoor temperature is higher than usual.
Frequently open the door.
The door is not closed completely.
Temperature control is not set correctly.

Summary of Contents for WHS-199BSS1

Page 1: ...WHS 209BESS1...

Page 2: ...ons may result in product damages or endanger the personal safety of users The symbols indicate matters that must be followed and those behaviors must be strictly executed in line with the operation r...

Page 3: ...cessible to water do not affect the electrical insulation performance of beer machine Since folding cardboard and plastic film may cause choking danger don t give the packing or other parts to childre...

Page 4: ...e temperature is adjustable The fault display will be restored after15 seconds later Rapid refrigeration function will be used only for the first barrel of beer in the box desiring to use as soon as p...

Page 5: ...letely Check and find the correct distance to hold glass from faucet when drawing Proper foam should be a tight creamy head and the collar on the average glass should be 3 4 to 1 high Beer drawn witho...

Page 6: ...rrels is 38 to 40 WILD BEER Beer when drawn is all foam or too much foam and not enough liquid beer Causes Corrections 1 Improper drawing beer into glass 1 Open faucet quickly and completely Check and...

Page 7: ...not so evident Wherever possible CO Gas should be used as 2 pressure source In high pressure systems where CO gas cannot be 2 sued a banner air gas Blender should be installed This introduces a small...

Page 8: ...CO gas cylinder 2 Outlet of CO gas cylinder 2 Main switch of CO gas cylinder 2 CO regulator valve 2 Regulating table Hex nuts port Regulating knob Safety switch Round air outlet Universal wheels witho...

Page 9: ...heCO regulator valve with CO tank closely Then remove the fixed 2 2 bolt of CO tank to remove CO tank finally by a wrench 2 2 In the process of installation ensure that all parts are connected tightly...