background image

W

Alternative method of installation if external 

support cannot be provided.

FLASH OR SEAL AROUND EXTERNAL 

WALL FRAME OR ARCHITRAVE

STURDY TIMBER

FRAME

TIMBER FRAMED 

ALL OR PARTITION

SOLID TIMBER SUPPORT

STEADYING BRACKET

(ONE PER SIDE)

DRAIN PAN

ENSURE LOUVRES

ARE ENTIRELY 

OUTSIDE THE WALL

Step 1

Slide the unit into the housing until it is firmly against the 

rear of the housing. Care is required  to ensure the foam 

sealing strips on the housing remain in position.

Step 2

Connect the air conditioner to the power and position the 

excess cord length beneath the air conditioner base.

Step 3

Engage the chassis fixing brackets into the bottom housing 

rail and secure to the base with the screw

provided.

Step 4

Remove the front panel from it’s carton and plastic bag and 

fit as per the Installation Instruction.

Step 5

Switch unit on. Check for operation of the unit and check for 

vibration in the installation.

Step 6

Fit the drain pan to the housing and run a drain line to a 

suitable location if required. 

AIR IN

AIR IN

AIR OUT

100mm minimum

OPTION A

AIR IN

LOUVRE

BRICK

WALL

O

45  BRICK CUT AWAY

 

TO CLEAR LOUVRES

FRONT

AIR OUT

AIR IN

AIR IN

TOP

VIEW

O

45  BRICK CUT AWAY 

TO CLEAR LOUVRES

100mm

BRICK

WALL

100mm

OPTION B

Installations of the unit into the wall

Installations of the unit into the housing

Step 4. Install the frame

     Fix the screws on the frame (See Fig.3).
Step 5. Install the air filter and front panel

a. Install the air filter into the frame’s slot from upside to underside

    (See Fig.2).

b. Hang the front panel on the frame’s buckle, then press the front

    panel into the frame’s slot until you hear a click (See Fig.10). 

6

4

5

Installations steps

Step 1. Remove the front panel and the air filter

a. Hold the slot under the front panel, then uplift it outwards, and remove the front panel (See Fig.1).

b. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from

    underside to upside (See Fig.2).

Step 2. Remove the frame

a. Remove the two fixing screws from the frame (See Fig.3).

b. Grasp the left corner of the frame’s underside, release the coupler plugs, then loosen the frame

    (See Fig.4).
Step 3. Installation

a. Remove the two fixing screws on the chassis fixing brackets, then remove the chassis fixing brackets

    (See Fig.5).

b. Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet (See Fig.6).

c. Remove shipping pad from around compressor before operation and make sure the discharge points

    to the

15

16

Summary of Contents for RG15A1/E

Page 1: ...r dealer or manufacturer for details For more information please visit our website www midea com ph A quality product of Window Type Inverter Model Customer Care 02 863 55 22 Landline 0917 8425555 SMS...

Page 2: ...iance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision and i...

Page 3: ...itted to be stored together will be determined by local regulations 6 Information on servicing 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks a...

Page 4: ...t disassemble or modify unit It may cause failure and electric shock It may cause an explosion or fire Do not use the power cord close to heating appliances Do not open the unit during operation Do no...

Page 5: ...can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and circuit breaker are turned off Note Performance may be reduced outside of the...

Page 6: ...water should be below 40 C to prevent distortion of the lter 4 Rinse o and gently shake o excess water from the ter Allow the lter to dry before replacing it To prevent distortion of the lter do not...

Page 7: ...coin vertically in the groove on the battery cover clockwise rotation of 45 degrees make sure that the groove is aligned with the unlock sign and remove the battery cover as shown below Step 2 Instal...

Page 8: ...RG15A1 B E RG15A2 B E RG15A1 B E RG15A2 B E Function buttons Push this button to decrease the indoor temperature setting Press this button to activate the Sleep mode This function is available on COOL...

Page 9: ...utomatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually NOTE 1 3 3 2 1 3 3 2 1 3 2 1 2 Dehumidifying operation Ensure the unit is plugged in and...

Page 10: ...is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavity should be sealed The housing sh...

Page 11: ...IN AIR IN TOP VIEW O 45 BRICK CUT AWAY TO CLEAR LOUVRES 100mm BRICK WALL 100mm OPTION B Installations of the unit into the wall Installations of the unit into the housing Step 4 Install the frame Fix...

Page 12: ...e filter Be sure the filter is thoroughly dry before putting it back Or instead of washing you may vacuum the filter to clean Note Never use hot water over 40 C 104 F to clean the air filter Never att...