background image

3. The selected time will register in 5 seconds

and the air conditioner will automatically

revert back to display the previous temper-

ature setting.

4. Turning the unit ON or OFF at any time

will cancel the Auto Start/stop function.

To cancel the TIMER setting, push

the TIMER button and press or hold the Up

( ) or Down(

) until 0 hour is displayed

on the LCD window of the air conditioner.

NOTE:

1

Swing operation

Use the SWING button to adjust the Left/Right

airflow direction.

1. Pressing this button while the unit is operational

will make the vertical louvers automatically swing

right and left, sweeping the cold/hot air alternately

to obtain comfortable cooling/heating.

2. Press the SWING button again to stop the

swing operation.

Over 50cm

FENCE

AWNING

75

-1

50

cm

Over 50cm

O

About 3~4

FENCE

AWNING

75

-1

50

cm

CAUTION

O

About 3~4

 

Preferred method of installation into a timber 

framed wall, partition or window.

FLASH OR SEAL AROUND EXTERNAL 

WALL FRAME OR ARCHITRAVE

STURDY TIMBER

FRAME ALL ROUND 

UNIT

TIMBER FRAMED 

WALL OR PARTITION

EXTERNAL SUPPORT 

FRAME AT BALANCE

POINT OF A/C

ALTERNATIVELY, BRACKETS 

AS ILLUSTRATED BELOW

MAY BE USED.

DRAIN PAN

Step 1

Remove the air conditioner from its packaging, 

remove fixing screws and slide the air conditioner 

out from the housing. (Refer to Installation Steps).
Step 2

Prepare the hole in the wall so that the bottom of the 

housing is well supported, the top has minimum 

clearance and the air inlet louvers have clearance 

as shown below in options A and B. Holes from the 

outside through to the cavity should be sealed. The 

housing should slope down towards the rear by 

about 5mm to allow water formed during operation 

to drain.
Step 3

Install the housing into the wall and ensure the foam 

seals are not damaged. Seal or fill the gaps around 

the inside and outside to provide satisfactory 

appearance and protection against the weather, 

insects and rodents.

Note: Unit may be supported by a  

          solid frame from below or by a  

          hanger from a solid overhead  

          support.

INSTALLATION INSTRUCTIONS

Select the Best Location

1. To avoid vibration and noise, make sure the units is installed securely and firmly.

2. Install the unit where the sunlight does not shine directly on it.

    If the unit receives direct sunlight, build an awning to shade the cabinet.

3. There should be no obstacle, such as a fence or wall within 50 cm from the back  

    of the cabinet because it will prevent heat radiation on the condenser. Restriction  

    of outside air will greatly reduce the cooling efficiency of the air conditioner.

4. Install the unit a little obliquely outward so the codensed water will not leak into

    the room (about 3~4° with level).

5. Install the unit with its bottom portion 75~150 cm above the floor level.

6. The power cord must be connected to an independent circuit. The yellow/green  

    wire must be grounded.

All side louvers of the cabinet must remain exposed to the outside of the structure.

Installation of the Housing

13

14

Summary of Contents for RG15A1/E

Page 1: ...r dealer or manufacturer for details For more information please visit our website www midea com ph A quality product of Window Type Inverter Model Customer Care 02 863 55 22 Landline 0917 8425555 SMS...

Page 2: ...iance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision and i...

Page 3: ...itted to be stored together will be determined by local regulations 6 Information on servicing 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks a...

Page 4: ...t disassemble or modify unit It may cause failure and electric shock It may cause an explosion or fire Do not use the power cord close to heating appliances Do not open the unit during operation Do no...

Page 5: ...can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and circuit breaker are turned off Note Performance may be reduced outside of the...

Page 6: ...water should be below 40 C to prevent distortion of the lter 4 Rinse o and gently shake o excess water from the ter Allow the lter to dry before replacing it To prevent distortion of the lter do not...

Page 7: ...coin vertically in the groove on the battery cover clockwise rotation of 45 degrees make sure that the groove is aligned with the unlock sign and remove the battery cover as shown below Step 2 Instal...

Page 8: ...RG15A1 B E RG15A2 B E RG15A1 B E RG15A2 B E Function buttons Push this button to decrease the indoor temperature setting Press this button to activate the Sleep mode This function is available on COOL...

Page 9: ...utomatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually NOTE 1 3 3 2 1 3 3 2 1 3 2 1 2 Dehumidifying operation Ensure the unit is plugged in and...

Page 10: ...is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the outside through to the cavity should be sealed The housing sh...

Page 11: ...IN AIR IN TOP VIEW O 45 BRICK CUT AWAY TO CLEAR LOUVRES 100mm BRICK WALL 100mm OPTION B Installations of the unit into the wall Installations of the unit into the housing Step 4 Install the frame Fix...

Page 12: ...e filter Be sure the filter is thoroughly dry before putting it back Or instead of washing you may vacuum the filter to clean Note Never use hot water over 40 C 104 F to clean the air filter Never att...

Reviews: