background image

Symbol

Value

Unit

Unit

Pnom

2.000

kW

No

Pmin

1.200

kW

No

Pmax,c

2.000

kW

No

---

---

---

No

elmax

1.933

kW

elmin

1.352

kW

No

elSB

0.000

kW

No

Yes

No
No
No

No
No
No
No
No
No

Verdict

correction factor accounting for a negative contribution to the seasonal space heating energy
efficiency by energy consumption of a permanent pilot flame-F(5)

0%

Seasonal space heating energy efficiency-η

S

36.00%

Verdict

P

100%

The electric to primary energy ‘conversion coefficient-CC

2.5

correction factor accounting for a positive contribution to the seasonal space heating energy
efficiency of electric storage local space heaters due to adjusted contributions for options for
heat storage and output; and a negative contribution to seasonal space heating efficiency for
commercial local space heaters due to adjusted contributions for options for the heat output-
F(1)

0%

correction factor accounting for a positive contribution to the seasonal space heating energy
efficiency due to adjusted contributions of controls of indoor heating comfort, the values of
which are mutually exclusive, cannot be added to each other-F(2)

6.00%

0 W

P

The power consumption of equipment in any condition
providing only information or status display, or
providing only a combination of reactivation function
and information or status display shall not exceed 1.00
W.

N/A

Description

Value

Seasonal space heating energy efficiency

with black bulb sensor

Contact details

GD Midea Environment Appliances MFG. Co., Ltd.
No. 28, Dong Fu Road, He Sui East Industrial Area, Dong Feng Town, Zhongshan, Guangdong,
China

Mode

Ecodesign requirements, from 7 January 2013

Result - Remark

Commission Regulation (EC) No 1275/2008 Requirement 

Test Data

with distance control option
with adaptive start control
with working time limitation

Other control options (multiple selections possible)

room temperature control, with presence detection
room temperature control, with open window detection

with electronic room temperature control
electronic room temperature control plus day timer
electronic room temperature control plus week timer

At minimum heat

single stage heat output and no room temperature

In standby mode

Two or more manual stages, no room temperature
with mechanic thermostat room temperature control

Maximum continuous
heat output

electronic heat charge control with room and/or
outdoor temperature feedback

Auxiliary electricity
consumption

fan assisted heat output

At nominal heat

Type of heat output/room temperature control (select one)

Item

Heat output

Type of heat input, for electric storage local space heaters
only (select one)

Nominal heat output

manual heat charge control, with integrated thermostat

Minimum heat output
(indicative)

manual heat charge control with room and/or outdoor
temperature feedback

Standby mode

Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any condition
providing only a reactivation function, or providing only
a reactivation function and a mere indication of
enabled reactivation function, shall not exceed 0.50 W.

correction factor accounting for a positive contribution to the seasonal space heating energy
efficiency due to adjusted contributions of controls for indoor heating comfort the values of
which can be added to each other-F(3)

0%

correction factor accounting for a negative contribution to the seasonal space heating energy
efficiency by auxiliary electricity consumption-F(4)

0%

Seasonal space heating energy efficiency in active mode-η

S,on

40%

For electric local space heaters-η

th

Off mode

Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W

0 W

P

Information requirment for the electric local space heaters

Model identifier(s):NTY20-16L, NT20-16A
Item

Summary of Contents for NT20-16A

Page 1: ...Pictures in the IM are for reference only PTC FAN HEATER MODEL NT20 16A GD Midea Environment Appliances MFG Co Ltd No 28 Dong Fu Road HeSui East Industrial Area Dong Feng Town ZhongShan GuangDong Chin...

Page 2: ...appliance Cleaning and user maintenance shall not be made by children without supervision 4 The heater must not be located immediately below a socket outlet 5 Do not use this heater in the immediate...

Page 3: ...duct This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste d...

Page 4: ...e controller is on adjust the Temperature Control knob to the desired temperature level Power Selection Knob Turn the Power selection knob to select between 3 functions Fan only Low 1200W LOW High 200...

Page 5: ...ng unaware that the heater is operating and maintaining the temperature of the room When you do not wish the heater to control the room temperature turn the control switch to O off and remove the plug...

Page 6: ...Other control options multiple selections possible room temperature control with presence detection room temperature control with open window detection with electronic room temperature control electr...

Page 7: ...er user maintenance is required orrecommended If service is required send your heater to the nearest authorized servicedepot 4 Store heater in a clean and dry place whennot in use REMEMBER portable el...

Reviews: