background image

 IMPORTANT

The cabinet and front panel may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid 

dishwashing detergent. Rinse thoroughly and wipe dry.

Do not 

use inflammable sprays such as lacquer or hair spray near the air conditioner

Do not 

use benzene, alcohol, gasoline, acid,paint thinner, polishing powder or other solvents to clean the unit. The unit can be damaged.

• 

• 

Do not 

use water hotter than 50°C (122°F) to clean the front panel. This can cause the panel to deform or become discolored. 

Excess water in or around the controls may cause damage to the air condtioner. Be sure to wring excess water from the cloth before wipe 

it clean. 

Cleaning Your Air Filter

A clogged air filter can reduce the cooling efficiency of your unit and 

increase operating noise.Make sure to clean the filter once every two 

weeks (or as necessary) during periods of frequent operation.  

 

1. Hold the slot under the front panel, then uplift it outwards, and 

remove the front panel.

2. Pinch the handle under the air filter and make the air filter arched, 

remove it from the slot from underside to upside(Model A). Grasp the 

handle of the filter, then slide it downwards to remove the filter(Model B).

3. Clean the filter with warm, soapy water. The water should be below 

40°C (104°F) to prevent distortion of the filter.

 

 
 

 

 

4. If your filter has a small air freshening filter, clean this air freshening 

filter with a hand-held vacuum. 

5. Rinse the air filter with fresh water, then shake off excess water. 

6. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.

 

Winter Storage

 CAUTION

NEVER

 operate the air conditioner without the 

air filter, as dust/dirt particles can contribute to 

equipment failure.

Model A

If your filter has a small air freshening 

filter(optional),it can be installed at 

any of the four positions, install it at 

the postion as you like . Clean it with 

a hand-held vacuum.

Model B

 

1

2
3

4

If you plan to store the air conditioner during the winter, remove it 

carefully from the window according to the installation instructions. 

Cover it with plastic or return it to the original carton.

WATER DRAINAGE

The condensed water can be treated as follows:

Bottom drainage 

(Applicable for the units designed with 

bottom drain hole only. )

- Remove the rubber plug from the bottom of cabinet(if any)

- Take out the drain pan and screws from accessary.

- Fix the drain pan onto the bottom of cabinet by screws.

- Connect an extension drain hose (locally purchased) to the 

  outlet of drain tray.

NOTE:

 The bottom drainage will slightly affect cooling perfo-

rmance, but it can reduce the noise caused by spraying the 

condensed water. For pump heating, the bottom drainage 

must be choosed.

Back drainage 

- Fit the seal onto the drain joint(provided as accessory).

- Insert the drain joint to the back drainage hole, and rotate 

  it by 90° to be well fitted.

- Connect an extension drain hose (locally purchased accor-

  ding to the installation length request) to the drain joint.

- Make sure to plug the bottom drain hole by rubble plug.

NOTE: 

The back drainage will slightly affect cooling perfor-

mance, but will reduce the noise caused by spraying the 

condensed water.

Back drain

hole

Back drain

hole

Drain

joint

Seal

Rubber

plug

Screw

Drain pan

Drain 

outlet

Rubber

plug

Rubber

plug

Bottom drain

hole

Bottom drain

hole

Bottom drainage

Back drainage

Non-drainage

 BEFORE CLEANING OR MAINTENANCE

 

ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY 
BEFORE CLEANING OR MAINTENANCE.

 

 

 

 

 

 

 

 

   

 

 

CARE AND MAINTENANCE

Cleaning Your Unit

8

 

Summary of Contents for MWF09HB4

Page 1: ...ation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference Please check the applicable mode...

Page 2: ...ispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take...

Page 3: ...or a prolonged period of time If the air conditioner is used together with burners or other heating devices thoroughly ventilate the room to avoid oxygen deficiency Safety Precautions Do not allow chi...

Page 4: ...ircuit breaker fuse rating should be the same as that of the power cord and wall outlet Power cord conductors are distinguished according to the color as shown in Wiring Diagram located on the top of...

Page 5: ...opical models Cooling operation Heating operation Outdoor Temperature Outdoor Temperature Indoor Temperature Indoor Temperature To further optimize the performance of your unit do the following Keep d...

Page 6: ...ressed the temperature decreases as follows 1 Celsius Scale Minimum Setting 17 16 TIMER on some models When the unit is on press the Timer button will initiate the Auto stop program the TIMER OFF indi...

Page 7: ...louver and move to the desired position see Fig D For some units the connecting rod of the louver is provided with a convex block it can be moved between the three grooves on the left side of frame a...

Page 8: ...ter as dust dirt particles can contribute to equipment failure Model A If your filter has a small air freshening filter optional it can be installed at any of the four positions install it at the post...

Page 9: ...educe the cooling and heating efficiency of the air conditioner 4 Install the unit a little obliquely downward to outside not to leak the condensed water into the room about 5 7mm 5 Install the unit w...

Page 10: ...6 Model D 1 Remove one screw securing the chassis fixing bracket then take down the chassis fixing bracket see Fig 5D 2 Remove four screws located on both sides and the back of the cabinet as shown in...

Page 11: ...gher number and then immediately turning back to a colder number Wait approximately 3 minutes Listen for compressor to start Air from unit does not feel cold enough Air conditioner cooling but room is...

Page 12: ...deepth of the panel may be slightly different So the dimension of D is for reference only 5000 6000 445x320x415 450x346x535 450x346x535 450x346x585 450x346x585 560x400x640 600x380x560 660x428x680 660...

Page 13: ...CS465 R031D E AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner...

Page 14: ...nt the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Handling the remote controller 2 2...

Page 15: ......

Page 16: ...range of 16 C 31 C in 1 C increments 4 Press the FAN button to select the fan speed in three steps Low Med or High Press the ON OFF button to start the air conditioner 2 Fan In the Fan mode you are no...

Page 17: ...depending on models NOTE To set Auto start time the unit must be in the Off position To set Auto stop time the unit must be in the On postion To set the Auto start time 1 Push the TIMER button when th...

Reviews: