4. Specification
MSG-30CRN1-QB9P
MSG-30HRN1-QB9P
Ph-V-Hz
1, 220-240V~,50Hz
1, 220-240V~,50Hz
Capacity
Btu/h
28000
28000
Input
W
2880
2880
Rated current
A
13.6
13.6
EER
Btu/w.h
10
10
Capacity
Btu/h
-----
30000
Input
W
-----
2760
Rated current
A
-----
13.2
COP
W/W
-----
11
A
19.5
19.5
A
63
63
Model
PA330X3CS-4MU1
PA330X3CS-4MU1
Type
Rotary
Rotary
Brand
GD TOSHIBA
GD TOSHIBA
Capacity
Btu/h
27876/27808
27876/27808
Input
W
2760/2990
2760/2990
Rated current(RLA)
A
13.1/13.7
13.1/13.7
Locked rotor Amp(LRA)
A
63
63
Thermal protector
Internal
Internal
Capacitor
uF
55
55
Refrigerant oil
ml
1100
1100
Model
YDK50-4E
YDK50-4E
Brand
Welling
Welling
Input
W
76/67/54
76/67/54
Capacitor
uF
3
μ
F/450V
3
μ
F/450V
Speed(hi/mi/lo) r/min
1260/1170/1000
1260/1170/1000
m3/h
1350/1200/1050
1350/1200/1050
dB(A)
52/49/45
52/49/45
Model
YDK100-6
YDK100-6
Brand
Welling
Welling
Input
W
169
169
Capacitor
uF
5
5
Speed
r/min
900
900
m
3
/h
1900
1900
dB(A)
≤
60
≤
60
g
R410A/2450
R410A/2450
MPa
4.2
4.2
Liquid side/ Gas side
mm
Ф
9.53/
Ф
16.0
Ф
9.53/
Ф
16.0
Max. refrigerant pipe length
m
20
20
Max. difference in level
m
10
10
℃
17-30
17-30
℃
18-45
-7 - 45
m
2
50~68
50~68
Model
Power supply
Cooling
Heating
Max. current
Starting current
Compressor
Indoor
fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat
different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.