Indoor Unit Disassembly 8
2.2 Electrical
parts
Note: Remove the front panel (refer to 1. Front panel) before disassembling electrical parts.
Procedure
Illustration
1) Remove the fi xing screw and then
remove the cover of electronic box and
the terminal cover (see CJ_MA_011).
2) Pull out the room temperature sensor
(T1) and the coil temperature sensor
(T2) (see CJ_MA_012).
3) Remove the two screws used for the
ground connection (see CJ_MA_012).
CJ_MA_011
CJ_MA_012
Note: This section is for reference only. Actual unit appearance may vary.
T1 Sensor
Ground Screws
T2 Sensor
Fixing Screw
Electronic Cover
Summary of Contents for MOAB30-09HFN8-QRD0GW
Page 1: ...BLANC INVERTER SERIES SM_MA GA _R32_INV_EU_NA_1909 SERVICE MANUAL ...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions ...
Page 18: ...Outdoor unit wiring diagram 16022000019533 ...
Page 20: ...Outdoor unit printed circuit board diagram 17122000040049 ...
Page 22: ...Outdoor unit printed circuit board diagram 17122000023675 ...
Page 24: ...Outdoor unit printed circuit board diagram 17122000036588 ...
Page 59: ... Outdoor Unit Disassembly 3 2 Dimension 1 Panel Plate AA01 ...
Page 60: ... Outdoor Unit Disassembly 4 2 Panel Plate AB01 ...
Page 61: ... Outdoor Unit Disassembly 5 3 Panel Plate BA01 ...
Page 62: ... Outdoor Unit Disassembly 6 For US models ...
Page 63: ... Outdoor Unit Disassembly 7 4 Panel Plate B01 ...
Page 64: ... Outdoor Unit Disassembly 8 For US models ...
Page 65: ... Outdoor Unit Disassembly 9 5 Panel Plate CA01 ...
Page 66: ... Outdoor Unit Disassembly 10 For US models ...
Page 67: ... Outdoor Unit Disassembly 11 6 Panel Plate D01 ...
Page 68: ... Outdoor Unit Disassembly 12 For US models ...
Page 69: ... Outdoor Unit Disassembly 13 7 Panel Plate X101 ...