Troubleshooting 9
Error code
Display
Error
Information
E0/EA
Indoor unit EEPROM parameter error
E1
Indoor / outdoor unit communication error
E2
Zero-crossing signal detection error
E3
The indoor fan speed is operating outside of the normal range
E60
Indoor room temperature sensor T1 is in open circuit or has short circuited
E61
Evaporator coil temperature sensor T2 is in open circuit or has short circuited
EC
Refrigerant leak detected
E
Indoor PCB/Display board communication error
F0
Current overload protection
E53
Outdoor room temperature sensor T4 is in open circuit or has short circuited
E52
Condenser coil temperature sensor T3 is in open circuit or has short circuited
E54
Compressor discharge temperature sensor TP is in open circuit or has short circuited
E51
Outdoor unit EEPROM parameter error
E7
The outdoor fan speed is operating outside of the normal range(
P0
IPM malfunction or IGBT over-strong current protection
P10
Over low voltage protection
P11
Over voltage protection
P12
DC voltage protection
P2
Compressor top high temperature protection (OLP)
P4
Inverter compressor drive error
P42
Compressor start error
P43
Lack of phase (3 phase) protection
P44
No speed protection
P45
341PWM error
P46
Compressor speed malfunction
P47
IPDU compressor lock
P48
IPDU compressor out of control
P49
Compressor over current protection
E8
Indoor units mode conflict(match with multi outdoor unit)
PA
Condenser high temperature protection
P6
Compressor discharge temperature protection
P81
Outdoor current protection
Summary of Contents for MOAB30-09HFN8-QRD0GW
Page 1: ...BLANC INVERTER SERIES SM_MA GA _R32_INV_EU_NA_1909 SERVICE MANUAL ...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions ...
Page 18: ...Outdoor unit wiring diagram 16022000019533 ...
Page 20: ...Outdoor unit printed circuit board diagram 17122000040049 ...
Page 22: ...Outdoor unit printed circuit board diagram 17122000023675 ...
Page 24: ...Outdoor unit printed circuit board diagram 17122000036588 ...
Page 59: ... Outdoor Unit Disassembly 3 2 Dimension 1 Panel Plate AA01 ...
Page 60: ... Outdoor Unit Disassembly 4 2 Panel Plate AB01 ...
Page 61: ... Outdoor Unit Disassembly 5 3 Panel Plate BA01 ...
Page 62: ... Outdoor Unit Disassembly 6 For US models ...
Page 63: ... Outdoor Unit Disassembly 7 4 Panel Plate B01 ...
Page 64: ... Outdoor Unit Disassembly 8 For US models ...
Page 65: ... Outdoor Unit Disassembly 9 5 Panel Plate CA01 ...
Page 66: ... Outdoor Unit Disassembly 10 For US models ...
Page 67: ... Outdoor Unit Disassembly 11 6 Panel Plate D01 ...
Page 68: ... Outdoor Unit Disassembly 12 For US models ...
Page 69: ... Outdoor Unit Disassembly 13 7 Panel Plate X101 ...