Owner’s & Installation manual

3. FUNCTIONS & FEATURES

Nested in the ceiling, space-saving and noble. 

High capcity of cooling / heating performance, high efficiency 

and energy-saving.

Adjust the indoor temperature rapidly and averagely.

Low noise design.

The air outlet is laid out in the way you desire.  

The air conditioner must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow this 

manual as strictly as possible.

If the air conditioner is installed on a metal part of the building, it 

must be electrically insulated according to the relevant 

standards to electrical appliances.

When all the installation work is finished, please turn on the 

power only after a thorough check.

Regret for no further announcement if there is any change of 

this manual caused by product improvement.

To install properly, please read this "Owner’s & Installation 

manual" at first.

2. INSTALLATION INFORMATION

Owner’s & installation manual

Accessory Name

Qty.

Sharp 

1

1

Purpose

This manual

4. ACCESSORIES

Table 4-1

DISPOSAL

Do not dispose this product as unsor-

ted municipal waste. Collection of such waste sepa-

rately for

 

special treatment is necessary.

Do not dispose of electrical appliances as unsorted 

municipal waste, use separate collection facilities.

Ground the air conditioner.

Do not connect the ground wire to gas or water pipes, 

lightning rod or a telephone ground wire.Incomplete 

grounding may result in electric shocks.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 

electric shocks.

Connect the outdoor unit wires , then connect the indoor 

unit wires.

 

You are not allow to connect the air conditioner with the 

power source until wiring and piping the air conditioner is 

done.

While following the instructions in this installation 

manual, install drain piping in order to ensure proper 

drainage and insulate piping in order to prevent 

condensation.

Improper drain piping may result in water leakage and 

property damage.

Install the indoor and outdoor units, power supply wiring 

and connecting wires at least 1 meter away from 

televisions or radios in order to prevent image 

interference or noise.

Depending on the radio waves, a distance of 1 meter may not 

be sufficient enough to eliminate the noise.

This appliance can be children  aged from 8 yeas and 

above and persons with reduced physical,sensory or 

mental capabilities or lack of experience and knowledge 

if they have been given supervision or instruction 

concerning use of the appliance in a safe way and 

understand the hazards involved.Childern shall not play 

with the appliance.Cheaning and user maintenance shall 

not be made by children without supervision.

Disconnect the power supply before cleaning and 

maintenance. Use dry cloth to clean the unit.

Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing 

in the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

Other special conditions.

CAUTION

NOTE

1

2

3

4

If air conditioner is used outside the above conditions, it 

may cause the unit to function abnormally.

The phenomenon is normal that the surface of air 

conditioning may condense water when the relative larger 

humidity in room, please close the door and window.

Optimum performance will be achieved within these 

operating temperature range.

Water system operating pressuer: Max: 1.6MPa, Min: 

0.15MPa. 

5. OPERATION RANGE

Use the system in the following temperature for safe and

effective operation.

Cooling operation

Heating operating

(cooling only type without)

Mode

Temperature

Outdoor

temperature

Room

temperature

Water inlet 

temperature

0°C

30°C

-15°C

24°C

0°C

43°C

Table 5-1

17°C

32°C

30°C

80°C

3°C

20°C

Accessional plastic water tray 

(

no air return box type without

Contact you local government for information regarding the 

collection systems available.

If electrical appliances are disposed of in landfills or dumps, 

hazardous substances can leak into the groundwater and get 

into the food chain, damaging your health and well-being.

Before installing the unit,it is necessary to check 

whether the ground wire is charged.

If it is,the unit shall not be installed before correction.

Summary of Contents for MKT2-V1000

Page 1: ...oil Unit Of Duct Type OWNER S INSTALLATION MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future refe...

Page 2: ......

Page 3: ...parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be i...

Page 4: ...revent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough to eliminate the noise This appliance can be children aged from 8 yeas and above and...

Page 5: ...h the construction and fit out staff Scope of dismantling the ceiling Please keep the ceiling horizontal Reinforce the beams and girders of the ceiling lest vibration of the ceiling Cut off the beams...

Page 6: ...cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire control switch see the installat...

Page 7: ...eiling by a rope 7 3 Connect the accessional plastic water tray no air return box type without Fig 7 10 Four pipe type unit mm Table 7 1 The quantities of the fans and motors are only for reference pl...

Page 8: ...ergo heat insulation treatment When performing the pipes connection use the rigid PVC binder and make sure that no leak exists Same as the joint of the indoor unit Be careful not to apply force at the...

Page 9: ...n fixed wiring The appliance shall be installed in accordance with national wiring regulations Be sure to locate the power wiring and the signal wring well to avoid cross disturbance Do not turn on th...

Page 10: ...CN1 CN5 MAIN BOAD MOTOR2 CN8 SW1 SW2 ON OFF S8 ON S6 OFF S7 S4 S5 YELLOW GREEN EARTH L HI MID LOW N N YELLOW GREEN POWER IN CN3 YELLOW BLUE RED BLACK Live wire Nuetral wire Ground wire Three speed swi...

Page 11: ...otor single m otor single m otor single m otor double m otor double m otor Not set models 10 2 The default model of DC fan coil is set as 12Pa when leaving the factory Clients can dial to the respond...

Page 12: ...A 51 44 35 dB contact details Information to identify the model s to w hich the information relation MODE MKT2 V300 Item Symbol Value Unit Cooling capacity sensible Prated c 2 82 kW Cooling capacity l...

Page 13: ...formation to identify the model s to w hich the information relation MODE MKT2 V800 Item Symbol Value Unit Cooling capacity sensible Prated c 6 67 kW Cooling capacity latent Prated c 1 25 kW Heating c...

Page 14: ...WA 50 44 37 dB contact details Information to identify the model s to w hich the information relation MODE MKT3 V300 Item Symbol Value Unit Cooling capacity sensible Prated c 3 1 kW Cooling capacity l...

Page 15: ...rmation to identify the model s to w hich the information relation MODE MKT3 V800 Item Symbol Value Unit Cooling capacity sensible Prated c 7 33 kW Cooling capacity latent Prated c 1 63 kW Heating cap...

Page 16: ...WA 50 44 35 dB contact details Information to identify the model s to w hich the information relation MODE MKT4 V300 Item Symbol Value Unit Cooling capacity sensible Prated c 3 09 kW Cooling capacity...

Page 17: ...nformation to identify the model s to w hich the information relation MODE MKT4 V800 Item Symbol Value Unit Cooling capacity sensible Prated c 6 66 kW Cooling capacity latent Prated c 1 38 kW Heating...

Page 18: ...45 0 38 7 dB contact details MODE MKT3 V300F Information to identify the model s to w hich the information relation Item Symbol Value Unit Cooling capacity sensible Prated c 2 445 kW Cooling capacity...

Page 19: ...2 52 2 44 4 dB contact details Information to identify the model s to w hich the information relation MODE MKT3 V800F Item Symbol Value Unit Cooling capacity sensible Prated c 6 036 kW Cooling capacit...

Page 20: ...16126200000003 V4 0...

Page 21: ...e ground wire is charged If it is the unit shall not be installed before correction 3 Before installing the unit be sure to confirm with the user whether there are wires water pipes air pipes and so o...

Reviews: