1.  Before Installation ........................................................................4
2.  Choosing an Installation Site ......................................................4
3.  Indoor Unit Installation..................................................................4
4.  Refrigerant Piping Installation ......................................................9
5.  Water Discharge Piping Installation ...........................................10
6.  Electrical Wiring .........................................................................10
7.  On-site Configuration ............................................................... 13
8.  Test Run.................................................................................... 14
9.  Part Names .............................................................................. 15

11. Air Conditioner Operations and Performance ........................... 16
12. Adjusting Air Flow Direction ...................................................... 17
13. Maintenance.............................................................................. 17
14. Symptoms That Are Not Faults ................................................ 18
15. Troubleshooting ........................................................................ 18

Safety Precautions
Read carefully before you install the air conditioner to make sure that 
the installation is correct.

There are two types of precautions as described below:
         Warning: Failure to comply may lead to death or serious injury.
         Caution: Failure to comply may lead to injury or damage of the 
unit. Depending on the situation, this may also lead to serious injury.
Once the installation is completed, and the unit has been tested and 
verified to be operating normally, please explain to the customer how 
to  use  and  maintain  the  unit  according  to  this  manual.  In  addition, 
make sure that the manual is kept properly for future reference.

 

  Install the air conditioner according to the steps described in this 

manual.  Improper  installation  may  cause  water  leakage,  electric 
shock, or fire.

  For  installation  in  smaller  rooms,  you  must  adopt  the  relevant 

measures to prevent the refrigerant concentration from exceeding 
the limit. Please consult the sales agent on the relevant measures 
required. A high concentration of refrigerant in an airtight space can 
cause oxygen insufficiency (anoxia).

  Make sure the required parts and accessories are installed. Using 

unspecified parts may cause the air conditioner to malfunction or 
drop, as well as water leakage, electric shock, and fire.

  Mount the air conditioner in a place that is sturdy enough to bear its 

weight. If the base is not secured properly, the air conditioner may 
drop leading to damages and injuries.

  Take in full consideration to the effects of strong winds, typhoons 

and earthquakes, and reinforce the installation. Improper installa-
tion may cause the air conditioner to drop leading to accidents.

  Make  sure  a  standalone  circuit  is  used  for  the  power  supply.  All 

electrical parts must comply with the local laws and regulations, and 
what is stated in this installation manual. The installation works must 
be carried out by a professional and qualified electrician. Insufficient 
capacity or improper electrical works can lead to electric shock or fire.

  Use only electrical cables that fulfil the specifications. All wiring on 

site must be carried out in accordance with the connection diagram 
attached to the product. Make sure that there are no external forces 
acting on the terminals and wires. Improper wiring and installation 
may cause a fire.

  Make sure the power cord, communication and controller wiring are 

straight and level when you are working on the connections, and the 
cover on the electric box is tight. If the electric box is not closed 
properly,  it  may  lead  to  electric  shock,  fire  or  overheating  of 
electrical components.

  If  the  refrigerant  leaks  during  installation,  open  the  doors  and 

windows immediately to ventilate the area. Refrigerant can produce 
toxic gases when in contact with fire.

  Switch  off  the  power  supply  before  touching  any  electrical 

component.

  To prevent electrical shock, do not touch a switch with wet hands. 

  Do not come in direct contact with the refrigerant leaking from the 

connections of refrigerant piping. Otherwise, it may lead to frostbite.

  The air conditioner must be grounded. Do not connect the earth line 

(ground)  to  gas  piping,  water  piping,  lightning  rods  or  telephone 
earth lines. Improper grounding can lead to electric shock or fire, 
and  may  cause  mechanical  failure  due  to  current  surges  from 
lightning and so on.

  The earth leakage circuit breaker must be installed. There is a risk 

of electric shock or fire if the earth leakage circuit breaker is not 
installed.

1

Warning

Installation Manual

Contents

Installation, maintenance and cleaning the filter work must be 
carried out by professional installers. Refrain from doing it yourself. 
Improper installation may cause water leakage, electric shock, or 
fire.

10. The Explain Of The Display Panel..............................................15

The appliance shall be installed in accordance with national wiring 
regulations.

The appliance must be installed 2,3m above floor.

If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or a similarly qualified person in 
order to avoid a hazard.
An all-pole disconnection switch having a contact separation of at 
least 3mm in all poles should be connected in fixed wiring.
The temperature of refrigerant circuit will be high, please keep the 
interconnection cable away from the copper tube.

The  power cord type designation is H05RN-For above/H07RN-F.

Accessories........................................................................................3

Installation Manual..............................................................................1

Check the power supply before installation. Ensure that the power 
supply must be reliably grounded following local, state and National 
Electrical Codes. If not, for example, if the ground wire  is detected  
charged, installation is prohibited before it is rectified. Otherwise, 
there is  a risk of fire and electric shock, causing physical injury or 
death. 

Check the electric wire, water and gas pipeline layout inside the 
wall, floor and ceiling before installation. Do not implement drilling 
unless confirm safety with the user, especially for the hidden 
power wire. An electroprobe can be used to test whether a wire is 
passing by at the drilling location, to prevent physical injury or 
death caused by insulation broken cords.

Summary of Contents for MI2-100Q4DHN1

Page 1: ...ion DC VRF indoor unit Installation and Operation Manual Original instructions Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Page 2: ......

Page 3: ...s and wires Improper wiring and installation may cause a fire Make sure the power cord communication and controller wiring are straight and level when you are working on the connections and the cover on the electric box is tight If the electric box is not closed properly it may lead to electric shock fire or overheating of electrical components If the refrigerant leaks during installation open the...

Page 4: ...ontent the mechanical parts will experience accelerated ageing which will severely compromise the service life of the unit 5 Where there are major voltage fluctuations Operating the unit using a power supply system that has large voltage fluctuations will reduce the service life of the electronic components and cause the unit s controller system to malfunction 6 Where there is a risk of leakage of...

Page 5: ...39 mm inner diameter 32 mm The inner diameter is based on the diameter of the copper and PVC pipes The thickness of the pipe casing is 10 mm or more Increase the thickness of the casing 20 mm or thicker when the temperature exceeds 30 C or the humidity exceeds RH80 To purchase based on actual project requirements Use to connect indoor refrigerant piping Use to discharge condensed water from the in...

Page 6: ...ections for the installation site See Figure 2 3 for the schematic on the direction of airflow If part of the air vent must be blocked you may insert an air baffle at the vent of the unit body to block the air flow See Figure 2 4 2 Choosing an Installation Site Figure 2 1 Panel Ceiling 910 mm ceiling hole position Air inlet Air outlet Air outlet Floor Connect to water piping outlet Figure 2 2 Conn...

Page 7: ...or mounting and drill four Φ12mm X 50 55 mm holes Then embed and set up the expansion hook anchors purchased accessory 4 in these holes See Figure 3 2 During the installation of the hooks purchased accessory 5 make sure that the concave portion of the hanger corresponds to that of the expansion hook anchors Determine the appropriate hook length for installation based on the ceiling s height Remove...

Page 8: ... Buffers Dimensions of unit ϕ75 fresh air vent Refrigerant piping vent liquid side C Refrigerant piping vent gas side D ϕ32 outer diameter of water discharge pipe Figure 3 10 Figure 3 11 Mounting hooks Master air conditioner Ceiling Panel Hex nut to adjust level All the figures in this manual are for illustration purposes only The actual air conditioner you purchased may not have the same appearan...

Page 9: ...ective casing to wrap the connection terminals and use a reliable fixture to secure and strengthen the safety isolation of the terminals 4 Adjust the four panel hook screws see Figure 3 15 c to keep the panel level and lift it evenly up to the ceiling 5 Adjust the panel slightly in the d direction see Figure 3 15 d so that the centre of the panel aligns with the centre of the opening of the ceilin...

Page 10: ... for the schematic on the installation dimensions of the air ducts Figure 3 22 See Figure 3 23 for the schematic on the air duct installation Figure 3 23 If only one air duct is connected The air volume in the air duct for the 5 6 8 0 kW model is about 300 360 m3 h The air volume in the air duct for the 9 0 14 0 kW models is about 400 640 m3 h Length of the air duct should not exceed 2 m If two ai...

Page 11: ...ssive torque will damage the socket cap and the cap will not be tight if you apply insufficient torque leading to leakages 4 5 Air Tightness Test Carry out the air tightness test on the system according to the instructions in the installation manual of the outdoor unit 4 7 Vacuum Create a vacuum in the system according to the instructions in the installation manual of the outdoor unit 4 8 Refriger...

Page 12: ... plugged to prevent water from leaking 5 Water Discharge Piping Installation 5 1 Water Discharge Piping Installation for Indoor Unit 1 Use PVC pipes for the water discharge pipes outer diameter 37 39 mm inner diameter 32 mm Based on the actual installation circumstance users can purchase the appropriate piping length from sales agent or local after sales service centre or purchase directly from th...

Page 13: ...connect the power cord firmly To prevent the cord from being pulled out by external force make sure it is fixed securely Figure 6 2 shows the power supply terminal of the indoor unit Refer to Tables 6 1 and 6 2 for the specifications of the power cord and communication wire A wiring capacity that is too small will cause the electrical wiring to become too hot and lead to accidents when the unit bu...

Page 14: ...adding the build out resistor at P and Q open Indoor and outdoor units Communication wire Connecting the shielded layer of the shielded wire Connect the shielded end of the shielded wire to the electronic controller box sheet metal here Signalling line between outdoor units Outdoor unit P Q Figure 6 6 The X1 X2 D1 D2 ports on the sides of the main control board and the unidirectional communication...

Page 15: ...unit in the system are not controlled by the centralized controller Caution The system can connect up to 64 indoor units address 0 63 at the same time Each indoor unit can only have one address DIP switch in the system The addresses of any two indoor units in the same system cannot be the same Units that have the same address may malfunction 0 1 definition of each dial code switch means 0 means 1 ...

Page 16: ...ad to electric shocks or injuries caused by moving parts such as the unit s fan Ensure that the power supply is disconnected before any servicing or maintenance is carried out Do not touch the unit or its remote controller with wet hands as doing so can lead to electric shocks Do not allow children to play near this unit as doing so risks injury Do not insert your fingers or other objects into the...

Page 17: ...igerant oil and other materials is adhered to Contact your local waste disposal authority for information about disposal procedures To avoid damaging the remote controller exercise caution when using it and replacing its batteries Do not place objects on top of it Do not place appliances that have naked flames under or near the unit as heat from the appliance can damage the unit Do not place the u...

Page 18: ...an air filters inside indoor units Caution The unit performs stably in the temperature range given in above table If the indoor temperature is outside the unit s normal operating range it may stop running and display an error code 16 Cooling mode Heating mode 17 32 C DB 15 27 C DB Indoor temperature Indoor humidity a Condensation will form on the unit surface and water dripping out of the unit whe...

Page 19: ...ell Clean the filter every two weeks when you use it regularly b If the air conditioner is positioned in a dusty place clean the filter often c Replace the filter if it is too dusty to clean the replaceable air filter is an optional fitting 1 Take out the air intake grille Push the grille switches simultaneously as indicated in Fig 13 1 Then pull down the air intake grille together with the air fi...

Page 20: ...t will start after the intentional delay is complete Heating mode is running when the following panel lights are on operation and the DEF FAN LED indicator Cause the indoor unit activates protective measures because of the low outlet temperature Caution When the power switch is connected some energy will be consumed even if the unit is not running Disconnect the power to save energy A degree of di...

Page 21: ...s air inlet or outlet is blocked A refrigerant leak has occurred Low heating effect Doors or windows are not completely closed Close doors and windows Arrange for a professional technician to check the following A refrigerant leak has occurred 15 2 Unit troubleshooting A power cut has occurred the power to the premises has been cut off Air flows normally but doesn t cool The unit starts or stops f...

Page 22: ... button is pressed Check whether the MODE indicated on the display is AUTO Check whether the MODE indicated on the display is DRY A power cut has occurred the power to the premises has been cut off Check whether the timer operation has come to an end when TIMER OFF is indicated on the display Check whether the timer operation has come to an end when TIMER ON is indicated on the display Check wheth...

Page 23: ...oil error Line loosened or broken The electronic expansion valve in stuck Outdoor unit error Water level float stuck Water level switch not connected properly Damaged main PCB Drain pump has malfunctioned 6 E 7 E b E error M O R P E E d E r o r r e t i n u r o o d t u O E E r o r r e l e v e l r e t a W FE Indoor unit has not been assigned an address Communication error between indoor and outdoor ...

Page 24: ...16126000002969 V G ...

Page 25: ...改前后核对和检查 B版本升级到C版本 更新整本说明书 C版本升级到D版本 P12添加线径说明 D版本升级到E版本 P12页删除图6 10 X1 X2接地 P12页6 3所有屏蔽线接地要求转移到6 3 1 E版本升级到F版本 P11表6 3 Cable for fixed wiring中的 and 为 to 图号升级 P16室内机制热温度增加下限 技术要求 双胶纸80克 黑白印刷 A4 V F V G 更改材质为80g 其余不变 ...