Wiring
MCAC-UTSM-2009-03
50
Installation
6. Wiring
6.1 MFA-12HRN1-Q (Quick connecter)
Attention:
Make sure the power supply has been cut off when inserting or pulling out the plug connecters.
1) The connection cables of indoor and outdoor units have been connected to the terminals on the control
board.
2) Remove the control cover from the outdoor unit by loosening the screw.
3) Hold the indoor plug connector and insert the mating plug connector located on the outdoor unit until it
fixed with a clicking sound. Secure the cable onto the control board with the cord clamp.
4) Connect the ground wire (yellow &green) reliably with sheet-metal by screws.
5) The electrical connection has finished now.
Connect the wire
Number
①
②
Area of the connecting wiring(mm
2
)
4×1.5
3×1.5
Summary of Contents for MFA-12HRN1
Page 2: ......
Page 9: ...MCAC UTSM 2009 03 Dimensions Indoor Units 7 2 Dimensions 3 Service Space...
Page 23: ...MCAC UTSM 2009 03 Wiring Diagrams Outdoor Units 21 5 Wiring Diagrams 5 1 MON 12HN1...
Page 24: ...Wiring Diagrams MCAC UTSM 2009 03 22 Outdoor Units 5 2 MON 18HN1...
Page 25: ...MCAC UTSM 2009 03 Wiring Diagrams Outdoor Units 23 5 3 MON 12HN1 Q...
Page 55: ...MCAC UTSM 2009 03 Wiring Installation 53 6 2 3 Wiring figure...
Page 58: ...Control MCAC UTSM 2009 03 56 Control Part 5 Control 1 Wireless remote controller R51D E 57...