Midea MDP30SR71 User Manual Download Page 14

  Page 14  

Ins

tallation

Ins

tructions

3

Installation Instructions

Positioning the Unit

more than 16in

Air outlet

more than

16in

more than 8in

more than

8in

more than

8in

A dehumidifier operating in a basement will have little or no effect in drying an 
adjacent enclosed storage area, such as a closet, unless there is adequate circulation 

of air in and out of the area. (See Fig. 13)

• 

Do not use outdoors.

• 

This dehumidifer is intended for indoor 
residential applications only. This 
dehumidifier should not be used for 
commercial or industrial applications.

• 

Place the dehumidifier on a smooth, 
level floor strong enough to support 
the unit with a full bucket of water.

• 

Allow at least 8 inches of air space on 
all sides of the unit for air circulation 
(at least 16 inches for air outlet).

• 

Place the unit in an area where the 
temperature will not fall below 41°F 
(5°C). The coils can become covered 
with frost at at lower temperatures, 
which may reduce performance.

• 

Place the unit away from any clothes 
dryer, heater or radiator.

• 

Close all doors, windows and other 
outside openings to the room.

Fig. 13

Summary of Contents for MDP30SR71

Page 1: ...fore using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with...

Page 2: ...this product Contact the authorized service technician for repair or maintenance of this unit The unit is not designed to be used by young children or people with reduced physical sensory or mental c...

Page 3: ...ug It may cause electric shock Do not allow water to touch into electric parts It may cause failure or electric shock Do not use the socket if it is loose or damaged It may cause fire and electric sho...

Page 4: ...n to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower...

Page 5: ...ng is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your unit must be used in a properly grounded wall receptacle If the wall receptacle y...

Page 6: ...e models Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar Front Product overview Accessories NOTE All the pictures in this manual are for ill...

Page 7: ...540 300 540 300 540 300 Water tank volume L 3 6 6 6 Air flow Hi Med Lo m3 h 234 219 320 280 320 280 320 280 CFM ft3 min 138 129 188 165 188 165 188 165 Noise level Hi Med Lo dB A 54 3 48 53 5 53 5 Co...

Page 8: ...ght Clean filter indicator light LED Display On Off Full Auto defrost FILTER Button This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illuminate after...

Page 9: ...r press the button and set a higher value TIMER Set Control Buttons Use the and key buttons to set the Timer ON or Timer OFF from 0 to 24 hours POWER Button Press to turn the dehumidifier on and off L...

Page 10: ...by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system w...

Page 11: ...The unit will restart operation when the bucket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit 3 Pour the water out Fig 5 Fig 6 NOTES When you...

Page 12: ...e water flow Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Select the desired humidity setting and fan speed on the unit for continuous drainin...

Page 13: ...lowing things Cleaning the pump filter Remove the bucket from the unit take down the pump and clean the pump filter See Fig 12 Check if the drain hose is clean and free of debris Empty the water of th...

Page 14: ...esidential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full...

Page 15: ...sh to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around i...

Page 16: ...ifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a water vapor source in the...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: