Oper

ating

Ins

tructions

NOTE

When the continuous draining feature is not being used, 
re

m

ove the drain hose fro

m

 the outlet, and dry the water 

in the continuous drain hose outlet.

2. Continuous draining

• 

Water can be automatically emptied into a floor drain 

by attaching the unit with a water hose (Id   Ø 5/16”, 

not included) with a female threaded end (ID: M = 1”, 

not included).

• 

Remove the plastic cover from the back drain outlet 
of the unit and set aside, then insert the drain hose 
through the drain outlet of the unit and lead the 
drain hose to the floor drain or a suitable drainage 
facility. (See Fig. 9 and Fig. 10)

• 

When you remove the plastic cover, if there is some 
water in the back drain outlet of the unit you must 
dry it. Make sure the hose is secure so there are no 
leaks and the end of the hose is level or down to let 
the water flow.

• 

Direct the hose toward the drain, making sure that 
there are no kinks that will stop the warter flowing.

• 

Select the desired humidity setting and fan speed on 
the unit for continuous draining to start.

Fig. 10

Fig. 9

Remove the
plastic cover
rotating counter-clockwise

Drain hose

Re

m

oving the Collected Water (cont.)

Fig. 11

3. Pu

m

p draining (Pu

m

m

odels only)

Water can be automatically emptied into a floor drain or 

a suitable drainage facility by attaching the pump drain 

out with a pump drain hose (Ø od = 1/4”, supplied).

• 

Remove the continuous drain hose from the unit and 

install the plastic cover to the continuous drain hose 

outlet of the unit by clockwise rotation. (See Fig. 11)

• 

Insert the pump drain hose into the pump drain hose 

outlet for at least 15mm (See Fig. 11), then lead the 

water hose to the floor drain or a suitable drainage 

facility.

• 

Press the pump pad on the unit to activate the 

pump operation. When the bucket is full the pump 

starts to work.

Pump drain
hose

Pump drain
hose outlet

Reinstall the
plastic cover

Summary of Contents for MDP30SR71

Page 1: ...fore using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with...

Page 2: ...this product Contact the authorized service technician for repair or maintenance of this unit The unit is not designed to be used by young children or people with reduced physical sensory or mental c...

Page 3: ...ug It may cause electric shock Do not allow water to touch into electric parts It may cause failure or electric shock Do not use the socket if it is loose or damaged It may cause fire and electric sho...

Page 4: ...n to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower...

Page 5: ...ng is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your unit must be used in a properly grounded wall receptacle If the wall receptacle y...

Page 6: ...e models Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar Front Product overview Accessories NOTE All the pictures in this manual are for ill...

Page 7: ...540 300 540 300 540 300 Water tank volume L 3 6 6 6 Air flow Hi Med Lo m3 h 234 219 320 280 320 280 320 280 CFM ft3 min 138 129 188 165 188 165 188 165 Noise level Hi Med Lo dB A 54 3 48 53 5 53 5 Co...

Page 8: ...ght Clean filter indicator light LED Display On Off Full Auto defrost FILTER Button This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illuminate after...

Page 9: ...r press the button and set a higher value TIMER Set Control Buttons Use the and key buttons to set the Timer ON or Timer OFF from 0 to 24 hours POWER Button Press to turn the dehumidifier on and off L...

Page 10: ...by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system w...

Page 11: ...The unit will restart operation when the bucket back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit 3 Pour the water out Fig 5 Fig 6 NOTES When you...

Page 12: ...e water flow Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Select the desired humidity setting and fan speed on the unit for continuous drainin...

Page 13: ...lowing things Cleaning the pump filter Remove the bucket from the unit take down the pump and clean the pump filter See Fig 12 Check if the drain hose is clean and free of debris Empty the water of th...

Page 14: ...esidential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full...

Page 15: ...sh to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it around i...

Page 16: ...ifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a water vapor source in the...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: