Service manual for portable washer Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
13
-
Drain valve failure.
Check and replace if failure
Water level switch failure.
Check the air pipe connected to the water
level switch. Replace if failure.
Check the water level switch. Replace if
failure.
PCBs failure.
Check and replace if failure.
E5
overflow
alarm
Water level switch failure.
Check the water level switch. Replace if
failure.
Water inlet valves, PCBs
failure.
Check and replace if failure.
E6
Lid lock
alarm
Lid broken
Check and replace if damaged.
Locker failure
Check and replace if failure
PCBs failure.
Check and replace if failure.
Note: E6 code is only for model MAE100-S2002GPS-M-13, MAM120-S2003GPS/M-13.
4.4 Wiring diagram and terminals
For model MAR30-P0501GP/US13
For model MAM50-S1103GPS/M-13, MAE50-S1102GPS/M-13, MAE70-S1402PS/M-SS13,
MAM70-S1403GPS/M-13 (No Door Switch), MAE70-S1402GPS/M-13 (No Door Switch)