Bucket Full Light

Lights up when the bucket is ready to be 
emptied.

Auto Shut Off

The dehumidifier shuts off when the bucket 
is full, or when the bucket is removed or not 
replaced in the proper position. When the 
set point humidity level is reached, the unit 
will be shut off automatically. The fan motor 
will continue operating.

Auto Defrost

When frost builds up on the evaporator 
coils, the compressor will cycle off 
and Auto Defrost function will run 
automatically.

3 minute compressor operation delay 
protection

After the unit has stopped, it can not be 
restarted in the first 3 minutes to protect 
compressor operation. The unit will restart 
automatically after 3 minutes.

Auto-Restart

If the unit stops unexpectedly due to a 
power cut, it will restart with the previous 
function setting automatically when the 
power resumes.

Setting the Timer ON and Timer OFF

•  When the unit is on, first press the 

Timer button, the Timer OFF indicator 
light illuminates. It indicates the Timer 
OFF program is initiated. Press it 
again the Timer ON indicator light 
illuminates. It indicates the Timer ON is 
initiated.

•  When the unit is off, first press the 

Timer button, the Timer ON indicator 
light illuminates. It indicates the Timer 
ON program is initiated. Press it 
again the Timer OFF indicator light 
illuminates. It indicates the Timer OFF 
is initiated.

•  Press or hold the   and   key buttons 

to change the Timer by 0.5 hour 
increments, up to 10 hours, then at 
1 hour increments up to 24 hours. 
The control will count down the time 
remaining until start.

•  The selected time will register 

in 5 seconds and the system will 
automatically revert back to display 
the previous humidity setting.

•  When the Timer ON and Timer 

OFF times are set, within the same 
program sequence, indicator lights 
illuminate identifying both ON and 
OFF times are now programmed.

•  Turning the unit ON or OFF at any time 

or adjusting the timer setting to 0.0 
will cancel the Timer function.

•  When LED display window displays 

the code of P2, the Auto Start/Stop 
function will also be cancelled.

NOTES

•  When first using the dehumidifier, 

operate the unit continuously 24 
hours. Make sure the plastic cap
on the drain hose outlet install  
stightly properly so there are no  
leaks.

•  This unit is designed to operate with 

a working environment between 
5°C/41°F and 32°C/90°F.

•  Make sure the water bucket is 

positioned correctly so that the unit 
can operate properly. When the 
water in the bucket reaches a certain 
level, please be careful while moving 
the unit to avoid it spill.

Oper

ating

Ins
tructions

Other Features

Summary of Contents for MAD20C1AWS

Page 1: ...Rated voltage 115V Frequency 60Hz MAD20C1AWS MAD25C1AWS MAD35C1AWS MAD50C1AWS Free 3 months extension of the original limited warranty period Simply text a picture of your proof of purchase to 1 844 2...

Page 2: ...Contact an authorized service technician for repair or maintenance of this unit The unit is not designed to be used by young children or people with reduced physical sensory or mental capabilities wit...

Page 3: ...ay cause electric shock Do not allow water to enter into electric parts It may cause failure or electric shock Do not use the power outlet if it is loose or damaged It may cause fire and electric shoc...

Page 4: ...ion to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flow...

Page 5: ...ic to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection again...

Page 6: ...ome models Power cord buckle placed in the water bucket used only when storing the unit Installed as shown below Re ar Front Product overview Accessories NOTE All the pictures in this manual are for i...

Page 7: ...se is installed into the unit and the drain hose is removed from the unit before the pump operation is activated When the bucket is full the pump starts to work Refer to the next pages for removing th...

Page 8: ...POWER Button Press to turn the dehumidifier on and off LED Display Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity...

Page 9: ...or light illuminates It indicates the Timer ON program is initiated Press it again the Timer OFF indicator light illuminates It indicates the Timer OFF is initiated Press or hold the and key buttons t...

Page 10: ...on when the bucket is back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit 3 Pour the water out Fig 5 Fig 6 NOTES When you remove the bucket do not...

Page 11: ...ow Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing Select the desired humidity setting and fan speed on the unit for continuous draining to start...

Page 12: ...owing items Cleaning the pump filter Remove the bucket from the unit take down the pump and clean the pump filter See Fig 12 Check if the drain hose is clean and free of debris Empty the water from th...

Page 13: ...dential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bu...

Page 14: ...brush to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild detergent Swish it arou...

Page 15: ...fier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a water vapor source in the...

Page 16: ...cover the following 1 Failure caused by damage to the unit while in your possesion other than damage caused by defect or malfunction by its improper installation or by unreasonable use of the unit inc...

Page 17: ......

Page 18: ......

Page 19: ...nna tre les d tails Version A 05 2019 Tension nominale 115V Fr quence 60Hz MAD20C1AWS MAD25C1AWS MAD30C1AWS MAD35C1AWS MAD50C1AWS Extension gratuite de 3 mois de la p riode de garantie limit e initial...

Page 20: ...ion et l entretien de cet appareil Veuillez contacter un technicien agr pour la r paration ou l entretien de cet appareil L appareil n est pas con u pour tre utilis par de jeunes enfants ou des person...

Page 21: ...urrait causer une lectrocution Ne pas mettre de l eau sur les composants lectriques Cela pourrait endommager l appareil ou causer une lectrocution Ne pas utiliser le cordon d alimentation s il est l c...

Page 22: ...minutieuse pour viter les blessures aux doigts ou la main Nettoyer le filtre toutes les deux semaines Si de l eau p n trait dans l appareil mettre celui ci l arr t le d brancher et contacter un techni...

Page 23: ...is la terre Afin de r duire les dangers associ s l lectrocution ou un incendie une mise la terre ad quate est essentielle Le cordon d alimentation est dot d une fiche trois broches mises la terre pour...

Page 24: ...ieur du r servoir utiliser uniquement lors du rangement de l appareil Installer comme montr ci dessous VUE ARRI RE VUE AVANT Vue d ensemble de l appareil Accessoires REMARQUE Toutes les images dans ce...

Page 25: ...le tuyau d vacuation de l eau de la pompe est install dans l appareil et que le tuyau d vacuation en continu est retir avant que le fonctionnement de la pompe ne soit activ Lorsque le r servoir est p...

Page 26: ...mettre en marche la minuterie ON ou l arr t OFF pour une p riode de 0 24 heures Bouton POWER Appuyer pour mettre en marche le d shumidificateur ou pour l arr ter Affichage DEL Affiche le taux d humid...

Page 27: ...ue l appareil est l arr t presser d abord le bouton de la minuterie Timer le t moin ON s allumera Cela signifie que l appareil est en marche En pressant nouveau le bouton de la minuterie Timer le t mo...

Page 28: ...a t remis en place 1 Retirer le r servoir 2 Maintenir les deux c t s du r servoir de fa on gale et le retirer de l appareil 3 Vider l eau Figure 5 Figure 6 REMARQUES Lors du retrait du r servoir ne p...

Page 29: ...t l eau de s couler S lectionner le r glage du taux d humidit et la vitesse du ventilateur afin que l vacuation continue de l eau commence vacuation de l eau recueillie suite 3 vacuation par la pompe...

Page 30: ...r le cordon d alimentation V rifier les l ments suivants Nettoyage du filtre de la pompe Retirer le r servoir de l appareil retirer la pompe et nettoyer le filtre consulter la Figure 12 V rifier si le...

Page 31: ...oit pas tre utilis dans un espace commercial ou industriel Placer le d shumidificateur sur un sol plat et de niveau suffisamment robuste pour soutenir le poids d un r servoir plein d eau Allouer un d...

Page 32: ...Nettoyer le r servoir Nettoyer r guli rement fond le r servoir afin d emp cher la croissance de moisissure champignons et bact ries Remplir partiellement le r servoir avec une eau propre et un d terg...

Page 33: ...l arri re du d shumidificateur Le r glage du taux d humidit n est peut tre pas suffisamment bas V rifier que toutes les portes fen tres et autres ouvertures sont bien ferm es La temp rature de la pi c...

Page 34: ...pas 1 Malfonctionnement en raison de dommages autres que le d faut de fabrication ou de pi ces installation non conforme utilisation non conforme abus incluant mais sans s y limiter le d faut d effec...

Page 35: ......

Page 36: ...Mettez vous l aise...

Reviews: