For MTBU-12HRDN1-M, MTBU-18HRDN1-M, MCA2U-12HRFN1-M, MCA2U-18HRFN1-M, MUBU-
12HRFN1-M, MUBU-18HRFN1-M:
Operatio
n
Timer
De-frost
Alarm
Failure
Display
ODU Error
code
★
X
X
X
Open or short circuit of T1 temperature sensor
E0
——
X
X
★
X
Open or short circuit of T2 temperature sensor
E1
——
X
★
X
X
Communication malfunction between indoor and
outdoor units
E2
E2
X
X
X
★
Full-water malfunction
E3
——
★
★
X
X
Indoor EEPROM malfunction
E4
——
★
X
X
IPM module protection
E5
P6
★
X
X
Open or short circuit of T3 or T4 temperature sensor
or outdoor EEPROM malfunction
E6
E0,E4
★
★
X
Outdoor fan has been out of control
E7
E8
★
X
Indoor fan speed has been out of control
F5
——
★
X
Voltage protection
P0
E5
★
X
X
Temperature protection of compressor top.
P1
P0
★
★
★
X
Outdoor unit over-current protection
P2
P3
★
◎
X
X
Inverter compressor drive protection
P4
——
★
X
Mode conflict
P5
——
★
flash at 2.5Hz,
light, X extinguished,
,
◎
flash at 0.5Hz
Note: Digital display is only available for duct type.
Oasis series:
Operation lamp Timer lamp
Display LED STATUS
ODU
Error
★
1 time
X
E0
Indoor EEPROM malfunction
——
★
2 times
X
E1
Communication malfunction between indoor and outdoor units
E2
★
4 times
X
E3
Indoor fan speed malfunction.
——
★
5 times
X
E4
Indoor room temperature sensor open or short circuit.
——
★
6 times
X
E5
Evaporator coil temperature sensor open or short circuit.
——
★
2 times
F1
Outdoor temperature sensor open or short circuit.
E4
★
3 times
F2
Condenser coil temperature sensor open or short circuit.
E4
★
4 times
F3
Compressor discharge pipe sensor open or short circuit.
E4
★
5 times
F4
Outdoor EEPROM malfunction
E0
★
6 times
F5
Outdoor fan has been out of control
E8
★
7 times
F6
Indoor unit coil outlet temp. sensor open or short circuit.
E4
Summary of Contents for M2OC-18HFN1-M
Page 19: ...8 Wiring Diagrams 8 1 Wiring diagram of 1 drive 2 outdoor M2OC 18HFN1 M M2OD 18HFN1 M...
Page 20: ...PCB board of M2OC 18HFN1 M M2OD 18HFN1 M...
Page 21: ...IPM board of M2OC 18HFN1 M...
Page 22: ...IPM board of M2OD 18HFN1 M...
Page 23: ...8 2 Wiring diagram of 1 drive 3 outdoor M3OD 27HRDN1 M M3OC 30HRFN1 M...
Page 24: ...PCB board of M3OC 30HRFN1 M...
Page 25: ...IPM board of M3OC 30HRFN1 M...
Page 26: ...PCB board of M3OD 27HRDN1 M...
Page 27: ...IPM board of M3OD 27HRDN1 M...
Page 28: ...8 3 Wiring diagram of 1 drive 4 outdoor M4OC 36HRFN1 M...
Page 29: ...PCB board of M4OC 36HRFN1 M...
Page 30: ...IPM board of M4OC 36HRFN1 M...
Page 31: ...PFC board of M4OC 36HRFN1 M...
Page 66: ...IPM for dual tri zone IPM for qua zone P N for dual tri zone...
Page 67: ...P N for qua zone...
Page 68: ...bridge rectifier for dual tri zone bridge rectifier for qua zone...
Page 69: ...Remark Measure the DC voltage between and port The normal value should be 190V 250V...
Page 71: ...Two ports of the inductance Inductance...
Page 72: ......
Page 77: ......
Page 79: ......
Page 81: ......
Page 83: ......
Page 96: ...6 EXV check Disconnect the connectors...
Page 98: ...Red Blue Red Yellow...
Page 99: ...Brown Orange Brown White...
Page 114: ...Screws of front panel Screws of right rear panel Screws of top cover...
Page 128: ......