background image

Installation of the heater

Installation of gas pipe

The operation of the installation can only be carried out
by authorized professionals.

Please pay attention to the special requirements for
installation made by the local country.

Please pay attention to the related regulations on the
bonding pressure of gas and gas types on the nameplate
of the heater.

Before connecting the gas pipe and water pipe to the
heater,please pay attention to the cleanout of these pipes
to remove impurities and other pollutants.

A sealing valve of G1/2 must be installed on the gas supply

pipe, as shown in the figure.

If necessary, please install a reductor on the gas supply pipe

(only for the butane supply)

Installation of water pipe and gas

pipe

Reduct or
Sealing valve
Output of hot water
Reduct or (optional)

Input of cold water

output pipe with

smell-proof sealing

fac ility (optional)

Installation of water pipe

Installation of exhaust pipe



A sealing valve shall be installed on the pipe of cold water, as

shown in the following figure.

The manufacturer recommends the installation of a reductor on

the cold water pipe.

In case of corrugated pipes, the minimum bending radius shall

be 20mm.

Connect the sealing valve to the attached cold water pipe.
Connect the sealing valve to the cold water input of the heater.
Connect the hot water output of the heater to the hot water pipe.

The heater should be equipped with an exhaust pipe or a
chimney. Please pay attention to the specific regulations for
installation required by the local country.

Only after finishing the installation of the exhaust pipe can the

heater be started for operation. Please pay attention to the require-
ments for the specification.

The parts of the exhaust pipe should be equipped with solid gas

funnel with water tightness.

The exhaust pipe cannot be oriented to ceiling.
An air intake should be introduced into the space of installation

in the place near ground.

Exhaust pipe

7

~~

Summary of Contents for JSD12-6DH4

Page 1: ...EATER GAS WATER HEATER Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference AUSTRALIA AND NEW ZEALAND GAS SAFETY CERTIFICATION DO NOT REMOVE ...

Page 2: ...tion and improper repair may cause human injury and even death Before thetrialrunning please read the service instruction The heater canbe only installed in a room with good ventilation Quality guarantee can beapplied foronly aftertrialrunning operated by professionals The heater corresponds torequirements of CEstandard and accord with the following directives 90 396 EWG legal Facilities directive...

Page 3: ...and make sure all of them are disconnected The heater and its components must be treated according to the locally effective prescriptions The manufacturer would not take responsibility for any damage caused by incorrect installation or use or by violation of the corresponding prescriptions Neither would the quality guarantee be offered Notices for the users Precautions for the water heater Repair ...

Page 4: ...pecial danger especially for the danger in state of electrical connection indicates heat gain in the parts on which any touch will cause injuries indicates specific environments indicates that there are relevant documents for reference or information attached indicates an interruption of installation or operation Indicates further information for the installer or the user Disorders elimination Mod...

Page 5: ...y valve to empty out the water inside Close the empty valve When flame goes out during the operation the heater will activate security thermostat In this case the gas feeding will be cut off automatically Only after the heater has cooled off can it ignite once again Please remain adequate ventilation of the exhaust outlet with caution Cool the heater off Turn off the water faucet and turn it on ag...

Page 6: ... materials are banned from being placed less than 500mm away from the heater If necessary please install an outer insulating layer The heater must be installed onto a vertical wall in a correct vertical way Installation order Confirm the drilling position according to the installation scheme or installation chart in the Speciation Table Open the close cover of the heater and pull out the operation...

Page 7: ...nal Installation of water pipe Installation of exhaust pipe A sealing valve shall be installed on the pipe of cold water as shown in the following figure The manufacturer recommends the installation of a reductor on the cold water pipe In case of corrugated pipes the minimum bending radius shall be 20mm Connect the sealing valve to the attached cold water pipe Connect the sealing valve to the cold...

Page 8: ...g out the following works of maintenance and repair Check whether the operation of exhaust system is in the perfect state Demount the burner and close the gas output in the case of no operation of the water heater Please clean burner and the gas nozzle with a brush and a vacuum cleaner Clean heat exchanger with a brush and a vacuum cleaner Remount the burner Check whether the ignition electrode an...

Page 9: ...on Cold water connection Hot water connection Flue gas pipe diameter Maximum temperature of exhaust pipe Q Hi 2 1 140 2 1 2 1 2 1 2 1 2 1 inch inch inch mm φ100 φ100 m m mm mm kg kg Flue gas pipe length Net dimensions net weight Dimensions Weight Gross dimensions net weight Dimensions Weight Max horizontal flue gas pipe Max vertical flue gas pipe 0 9 3 6 7 1 493x320x146 0 9 3 590x370x200 6 7 1 493...

Page 10: ...Dimensions and Specifications 10 106 5 786064 53 5 53 45 6 34 5 42 112 786104 53 48 67 53 71 A B C D E F 443 493 140 320 A B C 146 57 D E F 540 5 590 142 330 A B C 203 91 D E F ...

Page 11: ...ny Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signatu...

Page 12: ...make yourself at home ...

Reviews: