background image

Professional installers/ users

Notices for professional installers

The instruction for operation and installation is absolutely

necessary part of the heater and is provided along with the
heater. Please read the documents to guarantee that you
have comprehended all the data for an installation, operation
and safe service.

All specific adjustments and inspection for the heater must

be provided with the documents which entail the company seal
and signature of the installer.

The heater can be only installed onto the wall of a room without

frosts.

The installation can only be operated by qualified personnel

with reference to the instruction and additional documents
provided by the manufacturer. Attention should be paid to the
relevant prescriptions and norms as well as additional local
regulations.

Professional refers to a person who is familiar with technical

knowledge relevant to heating technology and drinking water
supply.

The heater can only be put into use under the appropriate

environmental condition.

Debugging and the inspection for the quality of gas along with

energy efficiency of the heater should be under the charge of
qualified professional installers.

As for user installation, specified adjustments should be done

only within the chapter

 

peration Manual?

During construction, the heater must be carefully protected

from dirt and other pollution.

The heater is only apt for the home water heating, and it should

be connected to a home water system corresponding to the
technical requirements of the heater.

The heater can only be installed for the anticipated operation

stated by manufacturer.

Do not leave the packing materials (cardboards, nails, bolts,

plastic plate and other similar materials) within reach of children.

All maintenance and repair can only be operated by authorized

professionals.

If necessary, please cut off the power supply before initiating

cleaning and maintenance.

Neither the seals nor stamps can be destroyed.
If it is necessary for definitive rupturing operation, please cut

off all the connections respectively (electrical power, hydraulic
power, gas feeding, exhaust pipe) and make sure all of them are
disconnected. The heater and its components must be treated
according to the locally effective prescriptions.
The manufacturer would not take responsibility for any damage
caused by incorrect installation or use, or by violation of the
corresponding prescriptions. Neither would the quality guarantee
be offered.

Notices for the users

Precautions for the water heater 

Repair and maintenance



Manual for installation and maintenance should be well kept.

If replacing the heater, please provide this manual to its
successor. For maintenance service, please give this manual
to professional serviceman for reference.

Maintenance, electric installation and inspection should be

operated by professionals.

In case of failure, please disconnect the power supply of the

heater immediately and make contact with its installer. Private
treatment to the failure is not allowed.

Neither the seals nor stamps can be destroyed.
Improper handling or manipulation may cause accidents.
No touches on hot parts of the heater such as all the tubes and

exhaust pipe.Any contact with hot parts can cause burn. Children
and laymen must keep remote from the heater during its operation.

For long-term nonuse of the heater, please close the valve and

take out the batteries. If necessary, please disconnect power
supply of the heater.

Any leakage from the heater to be found can be caused by parts

failure or deficient installation. Please make contact with its installer.

For regular operation of the heater, don't close intakes on the

door and wall.

No exposure of the heater in a steamy and greasy environment

such as place with a hearth.

No exposure of the heater in a place with water splash such as

bathroom and other wet environment.

No objects on the water heater.
Operation of the heater by children or laymen is not allowable,

neither is improper operation.

No blocking or obstruction at the entrance of the heater.

A clean and wet cloth can be used for the cleaning of the heater.
Dissolvent products are not allowed for the cleaning! Please only
clean exhaust pipe in cold state!

Repair and maintenance for the heater should be provided once

at least every year. It is recommended to provide repair and
maintenance after a period of heating.

All repair and maintenance should be carried out by authorized

professionals.

3

Summary of Contents for JSD12-6DH4

Page 1: ...EATER GAS WATER HEATER Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference AUSTRALIA AND NEW ZEALAND GAS SAFETY CERTIFICATION DO NOT REMOVE ...

Page 2: ...tion and improper repair may cause human injury and even death Before thetrialrunning please read the service instruction The heater canbe only installed in a room with good ventilation Quality guarantee can beapplied foronly aftertrialrunning operated by professionals The heater corresponds torequirements of CEstandard and accord with the following directives 90 396 EWG legal Facilities directive...

Page 3: ...and make sure all of them are disconnected The heater and its components must be treated according to the locally effective prescriptions The manufacturer would not take responsibility for any damage caused by incorrect installation or use or by violation of the corresponding prescriptions Neither would the quality guarantee be offered Notices for the users Precautions for the water heater Repair ...

Page 4: ...pecial danger especially for the danger in state of electrical connection indicates heat gain in the parts on which any touch will cause injuries indicates specific environments indicates that there are relevant documents for reference or information attached indicates an interruption of installation or operation Indicates further information for the installer or the user Disorders elimination Mod...

Page 5: ...y valve to empty out the water inside Close the empty valve When flame goes out during the operation the heater will activate security thermostat In this case the gas feeding will be cut off automatically Only after the heater has cooled off can it ignite once again Please remain adequate ventilation of the exhaust outlet with caution Cool the heater off Turn off the water faucet and turn it on ag...

Page 6: ... materials are banned from being placed less than 500mm away from the heater If necessary please install an outer insulating layer The heater must be installed onto a vertical wall in a correct vertical way Installation order Confirm the drilling position according to the installation scheme or installation chart in the Speciation Table Open the close cover of the heater and pull out the operation...

Page 7: ...nal Installation of water pipe Installation of exhaust pipe A sealing valve shall be installed on the pipe of cold water as shown in the following figure The manufacturer recommends the installation of a reductor on the cold water pipe In case of corrugated pipes the minimum bending radius shall be 20mm Connect the sealing valve to the attached cold water pipe Connect the sealing valve to the cold...

Page 8: ...g out the following works of maintenance and repair Check whether the operation of exhaust system is in the perfect state Demount the burner and close the gas output in the case of no operation of the water heater Please clean burner and the gas nozzle with a brush and a vacuum cleaner Clean heat exchanger with a brush and a vacuum cleaner Remount the burner Check whether the ignition electrode an...

Page 9: ...on Cold water connection Hot water connection Flue gas pipe diameter Maximum temperature of exhaust pipe Q Hi 2 1 140 2 1 2 1 2 1 2 1 2 1 inch inch inch mm φ100 φ100 m m mm mm kg kg Flue gas pipe length Net dimensions net weight Dimensions Weight Gross dimensions net weight Dimensions Weight Max horizontal flue gas pipe Max vertical flue gas pipe 0 9 3 6 7 1 493x320x146 0 9 3 590x370x200 6 7 1 493...

Page 10: ...Dimensions and Specifications 10 106 5 786064 53 5 53 45 6 34 5 42 112 786104 53 48 67 53 71 A B C D E F 443 493 140 320 A B C 146 57 D E F 540 5 590 142 330 A B C 203 91 D E F ...

Page 11: ...ny Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signature Authenticator for maintenance Maintenance content Maintenance personnel Company Stamp signatu...

Page 12: ...make yourself at home ...

Reviews: