26
8. Electronic function
8.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
TP: Compressor discharge temperature
8.2 Display function
8.2.1 Icon explanation on indoor display board.
Each time the “DISPLAY” button of remote controller is pressed, the display area displays in a
sequence of following:
Room temp. Outdoor ambient temp.
Setting temp. Display turns off
NOTE:
If the indoor/outdoor temperature sensor is failure, it will not display the indoor/outdoor
temperature.
Under inquiring, the indoor temperature flashes at 0.5HZ, and outdoor temperature flashes at
1HZ. If there is no button operation during 15 seconds, the set temperature will revert back to
the display window.
The actual room temperature and outside temperature can be displayed in a range of
-9.5
℃
-70
℃
Displays the malfunction code.
Summary of Contents for IC SI-A-1205