6.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas
Liquid
MSIC-09HRDN1-QC2+MOR-09HDN1-QC2
3/8’’
(Ф9.52
)
1/4’’
(Ф6.35)
5
8
20
20
MSIC-12HRDN1-QC2+MOR-12HDN1-QC2
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.
The oil trap should be installed per 5-7 meters.