M thermal Split
202004 45
Figure 4-2.6: MHA-V12(14,16)W/D2N8-B outdoor unit inverter module
1 2 3 4
5
6
7
10 9 11 8
Table 4-2.6: MHA-V12(14,16)W/D2N8-B outdoor unit inverter module
Label in
Figure 4-2.6
Code
Content
1
U
Compressor connection port U
2
V
Compressor connection port V
3
W
Compressor connection port W
4
CN19
Port for fan
5
CN20
Output port for +12V/9V
6
CN32
Port for communication with main PCB for filter board
7
CN23
Port for high pressure switch
8
CN6
Reserved
9
CN501
Input port L for rectifier bridge
10
CN502
Input port N for rectifier bridge
11
IC14
EEPROM
Midea CAC Confidential