Service Manual_2020-V1.0
41
7.9 Evaporator and Defrost system
Evaporator in freezing chamber
1
)
Remove the air duct components in freezing chamber.
2
)
Disconnect all connecting terminals.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove the evaporator to change a new one.
Defrost heater component on the evaporator
This product's defrosting sensor, fuse and defrosting
heater are integrated components, if only they do not
work, they can be replaced separately.
1
)
Disconnect the connecting terminals.
2
)
Cut off the band.
3
)
Use nipper plier to unlock all metal hooks of heater
pipe, separate the heater from the evaporator.
4
)
Change a new defrost heater component.
Summary of Contents for French-Door Series
Page 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None ...
Page 22: ...Service Manual_2020 V1 0 22 5 5 Inverter board terminal connection diagram Option ...
Page 74: ...Service Manual_2020 V1 0 74 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic ...
Page 75: ...Service Manual_2020 V1 0 75 ...
Page 76: ...Service Manual_2020 V1 0 76 11 2 No working of compressor ...
Page 77: ...Service Manual_2020 V1 0 77 11 3 Inside frosting no defrosting ...
Page 78: ...Service Manual_2020 V1 0 78 11 4 Inside frosting no defrosting Maintenance guidelines ...
Page 79: ...Service Manual_2020 V1 0 79 11 5 Light is not on ...
Page 80: ...Service Manual_2020 V1 0 80 11 6 Fan failure 11 7 Defective defrost circuit ...
Page 81: ...Service Manual_2020 V1 0 81 11 8 Noise 11 9 Air duct not operated ...
Page 82: ...Service Manual_2020 V1 0 82 11 10 Ice makernot make ice Option ...
Page 83: ...Service Manual_2020 V1 0 83 11 11 No ice or crushed ice falling off the distributor Option ...