Service Manual_2020-V1.0
18
Open door motor
DC120V 3W
Lights
Lights inside the freezing chamber
DC12V
、
1.2W
Lights inside the top of refrigerating
chamber
DC12V
、
1.2W
Lights inside both sides of
refrigerating chamber
DC12V
、
1.2W
Others Lights
None
Switch of the lights
■
Mechanical switch
□
Magnetism control switch
Other electrical parts
Water valve
AC110
~
127V
、
20W*2
Electric exchange valve
DC12V 5W
Defrosting parts
Defrosting sensor
NTC B3839 ( B5/25=3839K±2% )
Fuse in freezing chamber
AC120V
、
77(0,-4)
℃
Defrost heater in freezing chamber
AC115V
、
190W
Fuse in refrigerating chamber
AC120V
、
77(0,-4)
℃
Defrost heater in refrigerating
chamber
AC115V
、
90W
Summary of Contents for French-Door Series
Page 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None ...
Page 22: ...Service Manual_2020 V1 0 22 5 5 Inverter board terminal connection diagram Option ...
Page 74: ...Service Manual_2020 V1 0 74 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic ...
Page 75: ...Service Manual_2020 V1 0 75 ...
Page 76: ...Service Manual_2020 V1 0 76 11 2 No working of compressor ...
Page 77: ...Service Manual_2020 V1 0 77 11 3 Inside frosting no defrosting ...
Page 78: ...Service Manual_2020 V1 0 78 11 4 Inside frosting no defrosting Maintenance guidelines ...
Page 79: ...Service Manual_2020 V1 0 79 11 5 Light is not on ...
Page 80: ...Service Manual_2020 V1 0 80 11 6 Fan failure 11 7 Defective defrost circuit ...
Page 81: ...Service Manual_2020 V1 0 81 11 8 Noise 11 9 Air duct not operated ...
Page 82: ...Service Manual_2020 V1 0 82 11 10 Ice makernot make ice Option ...
Page 83: ...Service Manual_2020 V1 0 83 11 11 No ice or crushed ice falling off the distributor Option ...