29
8.4.2 Cooling Mode
8.4.2.1 Compressor and outdoor fan control
The action of the compressor and the outdoor fan are submitted to the following rule:
8.4.2.2 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected in high, medium, low and
auto speed.
Auto fan in cooling mode acts as follow:
8.4.2.3 Evaporator low temperature T2 protection.
When T2<
TE5
continuous for 5 min, the compressor and outdoor fan will stop and restart until
T2>
TE6
.