Service Manual
, 2016-12
24
/
45
1
)
Light of the refrigerating chamber is located upper
chamberRemove the screw.
2
)
Loosen the hook and remove the light.
Light switch
There is a light switch on the side wall of the
refrigerating chamber.
1
)
Loosen the hook with small normal screwdriver
and pull out the switch until the wire connector
reveals.
8.4
Air duct and fan motor
Air duct components in freezing chamber
All accessories in the freezing chamber should be
dismantled before removing the air duct components.
1
)
Remove 2 screws on the cover plate of the freezing
air duct using a cross screwdriver;
2
)
Pull out the connector terminal of the fan motor;
Fan motor
1
)
Disassemble buckles at the back of the freezing air
duct and remove 4 front cover plates;
2
)
Remove 3 screws using a cross screwdriver to get
the fan and components of fan brackets;
3
)
Remove 1 screws using a cross screwdriver to
separate fan brackets and the fan;
4
)
Separate the fan and fan blade (pull it out using
great force);
5
)
Replace the fan in reverse steps;
Summary of Contents for 22031020000113
Page 5: ...Service Manual 2016 12 5 45 1 Safety Warning Code 1 1Warning for operation safety ...
Page 6: ...Service Manual 2016 12 6 45 ...
Page 7: ...Service Manual 2016 12 7 45 ...
Page 8: ...Service Manual 2016 12 8 45 1 2Safety instruction for refrigerant ...
Page 17: ...Service Manual 2016 12 17 45 5 5Circuit diagram ...
Page 38: ...Service Manual 2016 12 38 45 11 2 Compressor failure ...
Page 39: ...Service Manual 2016 12 39 45 11 3 Defrosting is not working ...