background image

Installation & Owner‘s Manual

16

10.   MIDEA– HEAT PUMP MANUFACTUR-

        ER’S WARRANTY

This warranty is provided by Midea. It applies to heat pumps installed 

in a single family dwelling only and is provided only to those acquiring 

the heat pump as consumers within the meaning of the Australian 

Consumer Law.  The terms of the warranty are effective from the date 

the heat pump is installed.  Midea may verify this date by requesting a 

copy of the compliance certificate that accompanied the installation. 

The compliance certificate is mandatory in all Australian states and 

territories.  

10.1  Warranty period

Midea warrants that the following heat pump components will remain 

free of defects for the specified periods from the date of installation: 

•  Storage Tank - 5 years.

•  Compressor- 3 years.

•  All  other  components  supplied  by  Midea,  including  valves, 

elements, thermostats and sacrificial anodes - 1 year.

•  Midea gives no warranty in relation to components not supplied by

    Midea, for example tempering valves and cold water valve assem-

blies used by installers.

Subject  to  the  conditions  and  exclusions  specified  in  this  warranty, 

Midea will at its own  expense repair or replace any defective heat 

pump component covered by this warranty as  soon as reasonably 

practicable after the consumer has reported the defect to Midea.

10.2  Consumers must register the warranty

To be eligible to make a claim under this warranty, consumers must 

complete all details in the Installation Report & Warranty Registration 

form provided with the heat pump within 6 weeks of installation and 

send it to the address shown on the form.  

10.3 Procedure to make a claim under 

        warranty

Upon discovering a suspected defect, consumers should immediately 

report the suspected defect:

•  To the installer or supplier, if the suspected defect arises as a result 

of the installation of the heat pump or relates to any components 

not covered by this warranty.

•  To Midea on the phone number below during the relevant warranty 

period, if the suspected defect relates to any components covered 

by this warranty.

10.4 Specific exclusions

To the extent permitted by law Midea does not accept liability under 

this warranty:

1)  If any component of the heat pump has been installed, repaired, 

repositioned or modified by a person other than an appropriately 

qualified person approved by Midea in accordance with Midea’s 

installation and maintenance instructions and relevant local and 

statutory requirements;

2)  For loss or damage caused by a fault or defect in the installation 

of the heat pump;

3)  If corrosion has occurred because the anode has not been 

changed in accordance with the owner’s manual;

4)  If a cold water expansion valve, check valve and strainer is not 

fitted in areas where mains pressure is likely to exceed 500 kPa;

5)  For any damage arising as a result of an accident, act of God or 

other circumstances beyond Midea’s control;

6)  If the inner cylinder has collapsed as a result of an incorrect filling 

and/or commissioning procedure;

7)  For components not supplied by Midea that are used in the installa-

tion of Midea heat pump water heaters e.g. tempering valves, cold 

water valve assemblies, etc.

8)  For extended or implied warranties not formally provided by Midea;

9)  For external labour or equipment costs (e.g. cranes and lifting 

devices) required for repairs;

10) For costs incurred for rectifying faults (or perceived faults) not 

directly attributed to the Midea heat pump water heater;

11) For travel costs of service agents that exceed 30 kilometres; 

12) For all consequential loss or damage arising from defects that can 

lawfully be excluded;

13) For any other issues not directly attributable to defects in compo-

nents supplied by Midea including:

(a) Damage caused by incorrect commissioning;

(b) Leakage from valves not supplied by Midea;

(c) Leakage from the pressure temperature relief valve where the 

water pressure or temperature exceeds the limits specified in 

Midea’s installation and maintenance instructions;

(d) Water hammer;

(e) External rust on the storage tank;

(f) Insufficient hot water because:

(i) The consumer refuses to use the auxiliary booster;

(ii) Of an incorrectly set or faulty tempering or mixing valve;

(iii) Of faulty or incomplete installation;

(iv) The water heater is too small for its required purpose;

(v) Of insufficient water flow as a result of “water saving” tap-ware or 

appliances;

(vi) Of blown fuses, “tripped” electrical switches or inadequate house

-

hold electrical wiring;

(vii) Insufficient water flow caused by debris accumulating in water 

strainer.

10.5 Important Note

The benefits conferred by this warranty are in addition to any other 

rights and remedies available to the consumer under a law in relation 

to the goods or services to which the warranty relates.

Midea’s goods come with guarantees that cannot be excluded under 

the Australian Consumer Law. Consumers are entitled to a replace-

ment or refund for a major failure and for compensation for any other 

reasonably foreseeable loss or damage. Consumers are also entitled 

to have the goods repaired or replaced if the goods fail to be of accept-

able quality and the failure does not amount to a major failure.

Contact Phone:  1300 367 565.

Summary of Contents for 190RDN3-E

Page 1: ...ATION OWNER S MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference ALL IN ONE Type Air source Heat Pump Water...

Page 2: ...loding Continuous leakage of water from the valve may indicate a problem with the water heater THE INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AS NZS 3500 4 AS NZS 3000 and all local codes and r...

Page 3: ...anual When ordering repair parts please always give the following information 1 Model serial and product number 2 Part name on location Fan Assy PTR Valve Top Cover Evaporator Filter Magnesian Stick R...

Page 4: ...should be supervised to ensure that they do not play with the appliance NOTE Above calculations are based on ideal conditions the final amount will be different the actual running will vary with condi...

Page 5: ...be installed on a metal part of building make sure the electric insulation meets the relevant local electric standard 75 Gradient limit 75 CAUTION The earthing pole of socket must be well grounded ma...

Page 6: ...equire the water piping conden sate piping and drain piping to be insulated to shelter agianst freezing CAUTION CAUTION WARNING The unit must be securely fixed otherwise noise and vibartion may result...

Page 7: ...heat resistant and durable 2 Installation of the pipe for PTR valve The valve connecting thread is RC3 4 internal thread After installation it must be confirmed that the drainpipe outlet is exposed i...

Page 8: ...drain vent is at the lowest place Recommended inclination angle of unit to the ground should be no more than 2 Set the electric leakage protector according to the relevant electric technical standard...

Page 9: ...re found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint and varnish removers refrigerants and many other commercial and household products In addition excessive dust and...

Page 10: ...e system will defrost automatically to keep effective performance about 5 15min At defrosting time the compressor will stop but fan motor will still run Heat up Time There are different heat up times...

Page 11: ...tlet water is unclean Turn the tap on and the water will be flushed clean 5 2 3 Basic function 1 Weekly disinfect function Under disinfection mode unit immediately starts to heat water up to 65 to kil...

Page 12: ...heater Mode is selected at the off time ALARM When unit is displaying protection error will flash with 5Hz frequency as well as buzzer sounding 3 times every minute until protection error eliminated o...

Page 13: ...e will be extinguished CLOCK will be displayed all the time shows current clock on normal time shows setting clock when setting timer TIME CONFLICT Reserved function will be displayed if the timer whi...

Page 14: ...or more than 3 seconds and the Timer TIME ON TIME OFF function will be canceled INCREASE UP If button is unlocked corresponding value will increase by pushing When setting temperature press for more t...

Page 15: ...3 1 2 3 6 4 Auto restart If power is disconnected the unit can remember some of the setting parameters On or Off state operating mode setting water tempera ture when it re powers on the unit will be o...

Page 16: ...son to service the unit If PCB current_induction_circuit check the current difference between L N 14mA system consider it as electric leakage error Electric leakage error Compressor suction temperatur...

Page 17: ...draining exit The min heat resistance of the drain pipe is not less than 93 if the drain pipe can not meet the requirement please open the cold water inlet valve open the hot water tap until there is...

Page 18: ...e 40W Air out from sideward 440W 2150W 1 0MPa DN20 DN20 DN20 DN20 Default 63 38 70 adjustable T20A 250VAC 568 1580mm 190L 90kg 2780W 12 1A 1500W 2150W Water pipeline system RSJ 15 190RDN3 E Table 9 1...

Page 19: ...ult or defect in the installation of the heat pump 3 If corrosion has occurred because the anode has not been changed in accordance with the owner s manual 4 If a cold water expansion valve check valv...

Page 20: ...MDV11IU 055BW DZ 2020001A9998...