CAUTION

The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance.

Once the steamer is installed and all mechanical connections have been made, thoroughly test the steamer before 

operation.
1.   Check that proper water, drain and electrical and gas connections have been made.
2.   Turn main power switch ON.
3.   Check that “Ignition” light comes on when the pilot burner is on.
4.   After approximately 15 minutes, the “READY” light should come on, indicating that the water temperature is 205º 

Fahrenheit (97º Celsius). When the “READY” light comes on, set timer to the “5 minute” position. With door open, 

observe that no steam is entering the compartment and that the “COOKING” light is OFF.

5.   Close compartment door. The COOKING light should now illuminate and steam should be heard entering the 

compartment after about 45 seconds.

6.   After five minutes of operation check drain line to ensure that water from the cold water condenser is flowing through 

the drain line.

7.   Open compartment door and observe that steam supply to chamber is cut off. “READY” light should again come on as 

“COOKING” light turns “OFF”.

8.   Close compartment door and let cooking cycle finish. When the timer returns to “0” position, a buzzer will sound 

signaling the end of the cooking cycle. Buzzer must be manually turned off by setting the timer to its “OFF” position.

9.   With all compartments of the steamer operating in the cooking cycle, check the temperature of the condensate 

coming out the drain. If the drain temperature exceeds local plumbing code requirements, adjust the Thermostatic 

Cooling Valve (TCV) out for a lower drain temperature and in for a higher drain temperature. A TCV setting of 

approximately 2.75 yields a drain temperature of 140°F. A setting of approximately 2.5 or 3 yields temperatures of 

125°F and 155°F, respectively.

P

erformance

 C

heck

Summary of Contents for CROWN GSX-10HE

Page 1: ...______ WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly befo...

Page 2: ...tions thoroughly before installing operating or servicing this equipment NOTICE This manual should be retained for future reference NOTICE This product is intended for commercial use only NOT FOR HOUS...

Page 3: ...teamers RETAIN THIS MANUAL FOR FUTURE REFERENCE Table of Contents Important Notes For Installation and Operation 2 Service Connections 4 Installation Instructions 7 Performance Check 9 Operation 10 Ma...

Page 4: ...r cartridges replacement is required for warranty coverage Water supply to Crown Steam Group steamers must be within these guidelines Water which does not meet these standards should be treated with t...

Page 5: ...isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5...

Page 6: ...ith a connector that complies with the standard for connectors for moveable gas appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the standard for quickdisconnect device...

Page 7: ...teady supply pressure between 6 W C and 14 W C for natural gas and 12 W C and 14 W C for propane gas is recommended With all units operating simultaneously the manifold pressure on all units should no...

Page 8: ...to next section Performance Check for instructions to set the TCV Water Conditioning It is important that the water supplied to the generator be softened to no more than 2 0 grains of hardness and hav...

Page 9: ...nd steam should be heard entering the compartment after about 45 seconds 6 After five minutes of operation check drain line to ensure that water from the cold water condenser is flowing through the dr...

Page 10: ...se Your steamer has been factory set when ON to maintain water temperature during the READY phase at approximately 205 Fahrenheit 97 Celsius just below water boiling point CAUTION The appliance and it...

Page 11: ...cumulate against or clog the drain screen remove it clean it thoroughly and then replace it in its original position CONTROLS Ready Pilot Light When lit indicates steam generator has reached 205 Fahre...

Page 12: ...ional cooking time is necessary Cooking time for frozen foods depends on amount of defrosting required If time permits allow frozen foods to partially thaw overnight in a refrigerator This will reduce...

Page 13: ...and wash in sink 3 Wash compartment interior with clean water 4 Use warm soapy water with a cloth or sponge to clean exposed bead of door gasket rinse with warm clear water and wipe with a dry cloth W...

Page 14: ...possible in the direction of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burnt deposits which do not respond to the above procedure can...

Page 15: ...to drain 5 Flush cycle Turn on off switch to ON When ready light comes on switch to OFF to flush generator Repeat this step three times to completely flush generator 6 Clean exterior and interior Use...

Page 16: ...r scale or foreign particles lodged in diaphragm or core tube of valve These problems are an indication of severe harmful water conditions which should be corrected immediately to avoid damage to the...

Page 17: ...INSTALLATION OPERATION MANUAL 10124 REV 0 03 21 PAGE 17 OF20 Gas Fired Steamers Notes...

Page 18: ...INSTALLATION OPERATION MANUAL 10124 REV 0 03 21 PAGE 18 OF 20 Gas Fired Steamers Notes...

Page 19: ...INSTALLATION OPERATION MANUAL 10124 REV 0 03 21 PAGE 19 OF20 Gas Fired Steamers Notes...

Page 20: ...placement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Crown Authorized Service Agency or your dealer To avoi...

Reviews: