1) Wire all rear terminal blocks in parallel, for multiple sequence operation.

2) Front system power up/down switch is wired in parallel with rear remote terminal block. When wired together 

  as shown, pressing front System Power UP/DOWN switch on ANY sequencer will initiate system sequencing.

3) If remote power UP/DOWN is required, wire dry contacts in parallel. (single pole, double throw, center off,

  momentary switch)

4) Initiating system sequencing remotely: Sequencing can be initiated by either momentary dry contact or 

  maintained dry contact. Use of a maintained dry contact for system power up will reinitiate sequence after 

  power is restored from a power outage. When using maintained (not momentary) dry contact for remotely 

  controlling system sequencing, the front System Power UP/DOWN switches will be over-ridden.

NOTE: 

A flashing power (green) LED indicates that the system sequencing has begun.

DELAY BETWEEN SEQUENCES

.75 second interval between

each outlet power up/down

1.5 second interval between

each outlet power up/down

2.25 second interval between

each outlet power up/down

7 second interval between

each outlet power up/down

SEQUENCE UP/DOWN START DELAY

If 2 or 3 sequencers are to be used ("chained") together:

sequencer

#1

sequencer

#2

sequencer

#3

sequencer #1

sequencer #2

sequencer #3

1 2 3 4

1 2 3 4

1 2 3 4

first on
last off

second on
second off

last on
first off

up

com

down

up

com

down

up

com

down

DIP SWITCH SETTINGS:

optional

Installer provided
remote Switch

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

Page 4 

POWER
PDS-2x315R

-  115 Volt AC

-  Two 12 Amp circuits (24 Amps total)

-  Two 9' Power cords (14/3)

-  Standard NEMA 5-15 plugs

PROGRAMMING

-  Sequence delay start and interval between 

 

outlets timing functions controlled via front 

 

mounted dip switch

DIMENSIONS

-  19" Wide

-  1.75" High (1 space)

-  8.75" Deep

CONSTRUCTION

-  18 Gauge steel

-  Black powder coat finish

OUTPUT

-  7 Rear outputs (1 uncontrolled)

-  24 Amps total load (max)

-  12 Amps per circuit (max)

-  115 Volt AC

INTERCONNECTION

-  Rear remote control terminal block provides 

 

remote system power up/down. Multiple units

 

maybe chained together via simple parallel 

 wiring

-  Rear status terminal block, indicates 

 

sequence complete (Relay contact closure)

PROTECTION

-  Two 12 Amp circuit breakers located on front 

 panel 

 